OSHA Inspection: B. KING CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of B. KING CONSTRUCTION in 6675 N HEADWALL CIRCLE, APPLETON, WI 54913 (NAICS 238160). OSHA activity number 341200087.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B. King Construction for free Get an email when a new federal OSHA severe-injury report for B. King Construction is published. One employer, no account, unsubscribe in one click.
Site address
6675 N HEADWALL CIRCLE
City
APPLETON
State
WI
ZIP
54913
Mailing
10 E SMITH AVENUE, OSHKOSH, WI 54901
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
1
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 2, 2016
Abate by
Mar 2, 2016
Penalty
Initial $1,700 · Current $850 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a)  On or about 01-25-16 at 6675 N Headwall Circle in Appleton, an employee was working on a roof at thirteen (13) feet above surface level without utilizing fall protection equipment.
Recent events (2)
  • · I (S) $850
  • · Z (S) $1700

1926.503 A02 VIII

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 2, 2016
Abate by
Mar 9, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(2)(viii): The employer did not assure that each employee had been trained by a competent person qualified in the standards contained in subpart M:  a)  On or about 01-25-16, an employee was exposed to fall hazards without receiving safety training for installing proper fall protection equipment.  The employee was using a slide-guard which was installed along a roof eave edge on a 10:12 pitch roof surface as fall protection.