OSHA Inspection: MALINA CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MALINA CONSTRUCTION, INC. in 2195-2201 WASHINGTON DRIVE, NORTHBROOK, IL 60062 (NAICS 238130). OSHA activity number 341200160.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Malina Construction, INC. for free Get an email when a new federal OSHA severe-injury report for Malina Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2195-2201 WASHINGTON DRIVE
City
NORTHBROOK
State
IL
ZIP
60062
Mailing
419 E. SEEGERS #113, ARLINGTON HEIGHTS, IL 60005
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
Private (A)

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 26, 2016
Abate by
Feb 1, 2016
Penalty
Initial $1,600 · Current $900 Reduced
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:        a) Employees were exposed to eye injury while operating a nail gun without eye protection.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $900
  • · Z (S) $1600

1926.501 B13

Serious Gravity 10 4 instances 4 exposed
Issued
Jan 26, 2016
Abate by
Feb 1, 2016
Penalty
Initial $2,800 · Current $1,500 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):            a) Employees were exposed to the hazard of falling while performing carpentry work from first and second story roof deck surfaces without fall protection.             In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2800

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 26, 2016
Abate by
Feb 1, 2016
Penalty
Initial $2,400 · Current $1,600 Reduced
29 CFR 1926.1053(b)(4):  Ladder(s) were used for purposes other than the purpose for which they were designed:            a) Second Story Hallway - An 8 foot A-Frame stepladder was provided for employee use for access and egress between two points of the building.          In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $1600
  • · Z (S) $2400

1926.1053 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 26, 2016
Abate by
Feb 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:   a) Second Story Hallway - The top step of an 8 foot A-Frame stepladder was used as a step for access and egress between two points of the building.        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341200160.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.