SANDPOINT, ID ·
OSHA Inspection: OREGON CEDAR GRILL CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of OREGON CEDAR GRILL CORPORATION in 726 E SHINGLE MILL RD, SANDPOINT, ID 83864 (NAICS 321211). OSHA activity number 341204139.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OREGON CEDAR GRILL CORPORATION
- Site address
- 726 E SHINGLE MILL RD
- City
- SANDPOINT
- State
- ID
- ZIP
- 83864
- Mailing
- 26 E SHINGLE MILL RD, SANDPOINT, ID 83864
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321211
- Employees
- 50
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 2, 2016
- Abate by
- Jun 28, 2016
- Penalty
- Initial $1,785 · Current $893 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) In Wildwood Grilling Production area: On January 26, 2016 employees were exposed to being struck by fragments of Polyvinyl Chloride (PVC) plastic pipe in the event that the PVC plastic pipe ruptured. Plastic pipe was used in above ground locations throughout the facility to transport compressed air at 120 psi. The employer failed to follow ASME Gas Transmission and Distribution Piping Systems ASME B31.8-2010, Section 842.3.3 which prohibits the above ground use of PVC pipe for compressed air conveyance. Among other methods, one feasible and acceptable abatement for this hazard is to replace PVC piping and fittings with metal piping and fittings, which are rated to transport compressed air in exposed above ground locations.
Recent events (2)
- · I (S) $892.5
- · Z (S) $1785
1910.265 C18 I
- Issued
- Jun 2, 2016
- Abate by
- Jun 28, 2016
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.265(c)(18)(i): Pulley(s), sprocket(s), sheave(s), drum(s) and block(s) of conveyor(s) were not arranged to prevent the possibility of injury due to hands or parts of clothing being caught between the belt(s) and pulley(s) or chain(s) and sprocket(s) (a) At planar conveyor proximate to the south wall, On and before January 26, 2016, conveyor drums were not guarded in accordance with American National B.20 incorporated by reference (b) In the resaw area: On and before January 26, 2016, conveyor drums were not guarded in accordance with American National Standards B.20 incorporated by reference Note: Abatement certification is required for this item.
Recent events (2)
- · I (S) $1190
- · Z (S) $2380
More inspections in this industry (NAICS 321211)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341204139.