Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MJM ASSOCIATES CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MJM ASSOCIATES CONSTRUCTION LLC in 529 BROADWAY, NEW YORK, NY 10018 (NAICS 238990). OSHA activity number 341204709.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MJM Associates Construction LLC — free Get an email when a new federal OSHA severe-injury report for MJM Associates Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
529 BROADWAY
City
NEW YORK
State
NY
ZIP
10018
Mailing
511 CANAL STREET 6TH FLOOR, NEW YORK, NY 10013
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
28
Ownership type
A

5 citations on file for this inspection.

1926.453 B02 V

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jun 3, 2016
Penalty
Initial $3,850 · Current $0 Reduced
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:  a)  At the jobsite, adjacent to Spring Street, on or about 1/21/16:  Employees working inside an aerial lift were not attached to the boom or basket of that lift at approximately 40 feet from ground.
Recent events (3)
  • — R (S) $0
  • — C (S) $3850
  • — Z (S) $3850

1926.501 B01

Other-than-serious 1 instance 5 exposed
Issued
Jun 3, 2016
Penalty
Initial $5,390 · Current $3,750 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    a)  At the jobsite, on the 5th floor, on or about 1/21/16:  Employees were protected from falling more than 40 feet where an elevator shaft opening was unguarded at its front side.
Recent events (3)
  • — R (O) $3750
  • — C (S) $5390
  • — Z (S) $5390

1926.502 B01

Other-than-serious 3 instances 28 exposed
Issued
Jun 3, 2016
Penalty
Initial $3,850 · Current $1,700 Reduced
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:    a)  At the jobsite, on the 4th floor, at the stairwell, on or about 1/21/16:  The top edge of a guardrail system was not between 39 and 45 inches from the walking/working surface.  The top edge of this guardrail had sagged to 28 inches.    b)  At the jobsite, on the 4th floor, at the front opening of the elevator shaft, on or about 1/21/16:  The top edge of a guardrail system was not between 39 and 45 inches from the walking/working surface.  The top edge of this guardrail had been installed at 32 inches and had sagged to 24 inches.    c)  At the jobsite, on the 4th floor, at the rear opening of the elevator shaft, on or about 1/21/16:  The top edge of a guardrail system was not between 39 and 45 inches from the walking/working surface.  The top edge of this guardrail had been installed at 24 and 26 inches at its opposite end.
Recent events (3)
  • — R (O) $1700
  • — C (S) $3850
  • — Z (S) $3850

1926.760 A01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jun 3, 2016
Penalty
Initial $3,850 · Current $0 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.  a)  At the jobsite, on the 6th floor, on or about 1/21/16:  Workers were protected from falling 20 feet to the lower level while completing steel erection activities.
Recent events (3)
  • — R (S) $0
  • — C (S) $3850
  • — Z (S) $3850

1926.451 B01

Other-than-serious 2 instances 5 exposed
Issued
Jun 3, 2016
Penalty
Initial $6,160 · Current $6,000 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    a)  At the jobsite, in the basement, on or about 1/21/16:  Employees were working on tubular welded frame scaffolding where the working levels were not fully planked.    b)  At the jobsite, in the basement, on or about 1/21/16:  Employees were working on tubular welded frame scaffolding where the working levels were not  fully planked inside a pit.        MJM Associates Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926 451(b)(1), which was contained in OSHA inspection number 1040958, citation number 1, item number 1 and was affirmed as a final order on 6/22/15, with respect to a workplace located at 117 8th Avenue, Brooklyn, NY.
Recent events (3)
  • — R (O) $6000
  • — C (R) $6160
  • — Z (R) $6160

View MJM Associates Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341204709.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.