ASTORIA, OR —
OSHA Inspection: PERFORMANCE SYSTEMS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PERFORMANCE SYSTEMS INC. in COAST GUARD HOUSING, ASTORIA, OR 97103 (NAICS 238170). OSHA activity number 341208965.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PERFORMANCE SYSTEMS INC.
- Site address
- COAST GUARD HOUSING
- City
- ASTORIA
- State
- OR
- ZIP
- 97103
- Mailing
- 10111 S. TACOMA WAY STE. D1, LEWIS MCCHORD, WA 98499
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.453 B02 V
- Issued
- Feb 11, 2016
- Penalty
- Initial $2,625 · Current $2,625
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: (a) Coast Guard housing: On or about January 19th 2016 and times prior thereto, two employees were using a aerial lift for installing siding were not connected by their fall protection lanyard. This exposed the employees to a 10 foot fall hazard to the asphalt below.
Recent events (2)
- — I (O) $2625
- — Z (S) $2625
1926.503 A02 III
- Issued
- Feb 11, 2016
- Abate by
- Mar 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the correct use and operation of personal fall arrest equipment. Coast Guard housing: On or about January 19th 2016 and times prior thereto, two employees in an aerial lift did not have their lanyard connected and did not have their harness worn correctly. These hazards show that the employees need to be retrained on the correct use of personal fall arrest equipment.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Performance Systems INC.
View Performance Systems INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238170)