WASHINGTON, DC —
OSHA Inspection: SCHAUKOSKI GENERAL SERVICES LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of SCHAUKOSKI GENERAL SERVICES LLC in 3612 10TH STREET NW, WASHINGTON, DC 20016 (NAICS 238170). OSHA activity number 341210201.
Where did this inspection happen?
- Establishment
- SCHAUKOSKI GENERAL SERVICES LLC
- Site address
- 3612 10TH STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 3117 HEWITT AVE. APT. 501, SILVER SPRING, MD 20906
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights a) On or about January 6, 2016; south-side of residential home; the working platform on the two-point suspension ladder was not fully planked exposing employees to a 5-15 foot fall to the lower roof area; the platform missing one plank. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1600
1926.451 G01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system: a) On or about January 6, 2016; south-side of residential home; employee working off a two-point suspension scaffold without a guard rail system installed to help protect the employee from an estimated 5-15 foot fall to the lower levels while completing his assigned duties. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $0
1926.452 P02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(p)(2): The platform was not securely fastened to hangers (stirrups) by U-bolts or by other means which satisfy the requirements of 1926.451(a). a) On or about January 6, 2016; south-side of residential home; the working platform of the two-point suspension scaffold was not properly secured by stirrups or U-bolts exposing the employee to potential 5-15 foot fall to the lower roofs if displaced. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $0
1926.451 D03 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.451(d)(3)(i): Before the scaffold was used, direct connections were not evaluated by a competent person to confirm, based on the evaluation, that the supporting surfaces are capable of supporting the loads to be imposed: a) On or about January 6, 2016; south-side of residential home; the employer did not have a competent person to evaluate the two-point suspension scaffold system that he and the employees had erected. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1600
1926.502 D15
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee a) On or about January 6, 2016; south-side of residential home; the employer did not ensure that anchor point, used to for the personal fall protection equipment (full body harness), would be able to with stand 5000 pounds in the event of an incident. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1600
1926.1053 B04
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about January 6, 2016; south-side of residential home; the employees were using a 7 foot fiberglass step ladder in the closed position to access the work area exposing them to a 10 foot fall to the wooden deck. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1600
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341210201.