HORICON, WI —
OSHA Inspection: NEW HAMPSHIRE INDUSTRIES, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of NEW HAMPSHIRE INDUSTRIES, INC. in 300 INDUSTRIAL DRIVE, HORICON, WI 53032 (NAICS 332510). OSHA activity number 341212843.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEW HAMPSHIRE INDUSTRIES, INC.
- Site address
- 300 INDUSTRIAL DRIVE
- City
- HORICON
- State
- WI
- ZIP
- 53032
- Mailing
- 300 INDUSTRIAL DRIVE, HORICON, WI 53032
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332510
- Employees
- 48
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.132 A
- Issued
- Apr 15, 2016
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: On or about January 29, 2016 employees operating MIG welding machines were not wearing protective equipment to prevent burns from welding spatter.
Recent events (2)
- — I (S) $1620
- — Z (S) $2700
1910.133 A05
- Issued
- Apr 15, 2016
- Abate by
- May 13, 2016
- Penalty
- Initial $4,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.133(a)(5): The employer did not ensure that each affected employee used equipment with filter lenses that had a shade number appropriate for the work being performed for protection from injurious light radiation. On or about January 29, 2016, employee operating carousel 1070 spot welder were not wearing shaded eye protection.
Recent events (2)
- — I (S) $0
- — Z (S) $4500
1910.147 C04 I
- Issued
- Apr 15, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $5,400 · Current $3,240 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about January 29, 2016 energy control procedures were not developed for employees who cleared jams and or changed out parts on: a. 8 station carousel with spot welder b. 8 station carousel without spot welder
Recent events (2)
- — I (S) $3240
- — Z (S) $5400
1910.147 C04 II B
- Issued
- Apr 15, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about January 29, 2016 employees did not use energy control procedures to clear jams and or changed out parts on: a. 8 station carousel with spot welder b. 8 station carousel without spot welder
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D03
- Issued
- Apr 15, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $5,400 · Current $3,240 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about January 29, 2016 isolating devices were not used when employees cleared jams and or changed out parts on: a. 8 station carousel with spot welder b. 8 station carousel without spot welder
Recent events (2)
- — I (S) $3240
- — Z (S) $5400
1910.147 D04
- Issued
- Apr 15, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4): A lockout device was not attached to all power sources: On or about January 29, 2016 isolating devices were not used when employees cleared jams and or changed out parts on: a. 8 station carousel with spot welder b. 8 station carousel without spot welder
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Apr 15, 2016
- Penalty
- Initial $3,600 · Current $2,160 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about January 29, 2016 the slitter access door control logic circuit did not deactivate the rotating head.
Recent events (2)
- — I (S) $2160
- — Z (S) $3600
1910.217 C03 VII
- Issued
- Apr 15, 2016
- Penalty
- Initial $6,300 · Current $3,780 Reduced
General-duty citation text
29 CFR 1910.217(c)(3)(vii): Two hand control device(s) used on mechanical power press(es) were not located at a safe distance from the point of operation so that the slide completed the downward travel or stopped before the operator could reach into the point of operation: On or about January 29, 2016 the Verson strip punch press, Model number S1-300-48-48T s/n 13851, operator was exposed to a struck by hazard by the upper ram. The two hand controls were not in conformance to table 0-10 of 1910.217.
Recent events (2)
- — I (S) $3780
- — Z (S) $6300
1910.303 B02
- Issued
- Apr 15, 2016
- Penalty
- Initial $6,300 · Current $3,780 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about January 29, 2016 a metal knockout box was suspended freely by a ceiling mounted flexible cord and the strain relief was compromised.
Recent events (2)
- — I (S) $3780
- — Z (S) $6300
1910.305 G02 III
- Issued
- Apr 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about January 29, 2016 a metal knockout box was suspended freely by a ceiling mounted flexible cord and the strain relief was compromised.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at NEW Hampshire Industries, INC.
View NEW Hampshire Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332510)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341212843.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.