OSHA Inspection: TYCHE CONSTRUCTION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TYCHE CONSTRUCTION in 1523 GRAND AVE, WINDSOR, CO 80550 (NAICS 238170). OSHA activity number 341213775.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tyche Construction — free Get an email when a new federal OSHA severe-injury report for Tyche Construction is published. One employer, no account, unsubscribe in one click.
Establishment
TYCHE CONSTRUCTION
Site address
1523 GRAND AVE
City
WINDSOR
State
CO
ZIP
80550
Mailing
700 W 91ST AVE #A303, THORNTON, CO 80260
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.451 F07

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 30, 2016
Abate by
May 6, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(f)(7):  The scaffold was erected, moved, dismantled, or altered without the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling, or alteration:      (a)  Tyche Construction at 1523 Grand Ave, Windsor, CO 80550:  On or before October 7, 2015, the exposing employer did not ensure the pump jack scaffolding was erected, moved, dismantled, or altered with the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling, or alteration, in that an Alum-A-Pole Scaffolding System, platform width 21 inches, was used in conjunction with a Werner SPJ-100 Steel Pump Jack model number 2424, platform width 14 inches.  Employees used the scaffold to install siding and soffit backing on a two-story residential home.  This condition exposed employees to fall hazards of approximately 15 feet due to the difference in platform widths at the section where the platforms adjoined.      (b)  Tyche Construction at 1523 Grand Ave, Windsor, CO 80550:  On or before October 7, 2015, the exposing employer did not ensure the pump jack scaffolding was erected, moved, dismantled, or altered with the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling, or alteration, in that an Alum-A-Pole Scaffolding System, platform width 21 inches, was used in conjunction with a Werner SPJ-100 Steel Pump Jack model number 2424, platform width 14 inches.  Employees used the scaffold to install siding and soffit backing on a two-story residential home.  This condition exposed employees to a trip hazard at the section where the two platform ends adjoined due to one platform being approximately 5 inches higher.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.451 G04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 30, 2016
Abate by
Apr 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i):  Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:    (a)  Tyche Construction at 1523 Grand Ave, Windsor, CO 80550:  On or before October 7, 2015, the exposing employer did not ensure employees working on a pump jack scaffold were protected from falls by the use of guardrails along all open sides and ends of the scaffold, in that the end-rails installed on one end extended past the end of the house, thus creating an opening of approximately 1.5 feet.  This condition exposed employees to fall hazards of approximately 15 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 B

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 30, 2016
Abate by
May 6, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.454(b):  Employees involved in erecting, disassembling, moving, operating, repairing, maintaining or inspecting a scaffold were not trained by a competent person to recognize any hazards associated with the scaffold in question:      (a)  Tyche Construction at 1523 Grand Ave, Windsor, CO 80550:  On or before October 7, 2015, the exposing employer did not ensure employees were provided with adequate training concerning erecting, disassembling, moving, operating, repairing, maintaining or inspecting a scaffold, in that an Alum-A-Pole Scaffolding System, platform width 21 inches, was used in conjunction with a Werner SPJ-100 Steel Pump Jack model number 2424, platform width 14 inches.  Employees used the scaffold to install siding and soffit backing on a two-story residential home.  This condition exposed employees to fall hazards of approximately 15 feet due to the difference in platform widths at the section where the platforms adjoined.      (b)  Tyche Construction at 1523 Grand Ave, Windsor, CO 80550:  On or before October 7, 2015,   the exposing employer did not ensure employees were provided with adequate training concerning erecting, disassembling, moving, operating, repairing, maintaining or inspecting a scaffold, in that an Alum-A-Pole Scaffolding System, platform width 21 inches, was used in conjunction with a Werner SPJ-100 Steel Pump Jack model number 2424, platform width 14 inches.  Employees used the scaffold to install siding and soffit backing on a two-story residential home.  This condition exposed employees to a trip hazard at the section where the two platform ends adjoined due to one platform being approximately 5 inches higher.      Abatement Note:  Scaffolding manufacturers instructions shall be referenced and used in accordance with those instructions.       Abatement Note: The training shall include the following topics, as applicable:      1)     The nature of scaffold hazards;      2)     The correct procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold in question;      3)     The design criteria, maximum intended load-carrying capacity and intended use of the scaffold;      4)     Any other pertinent requirements of this subpart.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341213775.