PHILADELPHIA, PA —
OSHA Inspection: HUA DA CONSTRUCTION INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HUA DA CONSTRUCTION INC. in 934 ARCH STREET, PHILADELPHIA, PA 19107 (NAICS 236116). OSHA activity number 341214583.
Where did this inspection happen?
- Establishment
- HUA DA CONSTRUCTION INC.
- Site address
- 934 ARCH STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19107
- Mailing
- 917 ARCH STREET SUITE 102, PHILADELPHIA, PA 19107
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 4
- Ownership type
- A
Citations
10 citations on file for this inspection.
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) Jobsite - Employees engaged in block laying were exposed to a fall hazard greater than six (6) feet above the grade without fall protection. The employer did not utilize a personal fall protection system, guard rails or a safety net system to protect employees from falling. Observed on or about 29 January 2016.
Recent events (1)
- — Z (S) $2800
1926.501 B04 II
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers. a) Jobsite - Employees engaged in framing and welding operation at heights greater than six (6) were exposed to fall hazards through unprotected floor holes without the use of a fall protection system. Observed on or about 29 January 2016.
Recent events (1)
- — Z (S) $2800
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than 1 inch (2.5cm) wide, except where the employer can demonstrate that a wider space is necessary. a) Jobsite - The working level of the tubular welded frame scaffold was not fully planked or decked between the front and rear uprights thus exposing employees to a fall hazard of approximately ten (10) feet. Observed on or about 29 January 2016.
Recent events (1)
- — Z (S) $2800
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. a) Jobsite - Employees were not provided with a safe means of access and/or egress to the tubular welded frame scaffold platform, exposing employees to a fall hazard of approximately ten (10) feet. Employees were using the side frame of the scaffold to access and/or egress the working levels. Observed on or about 29 January 2016.
Recent events (1)
- — Z (S) $2800
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Jobsite - Employees performing welding operations on the tubular welded frame scaffold were exposed to fall hazards of greater than ten (10) feet without the use of personal fall arrest systems or guardrail systems. Observed on or about 29 January 2016.
Recent events (1)
- — Z (S) $2800
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) Jobsite - Employees were performing welding operations on a tubular welded frame scaffold that was not erected by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection. Observed on or about 29 January 2016.
Recent events (1)
- — Z (S) $2800
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) Jobsite - Employees installing siding were exposed to a collapse hazard as the tubular welded frame scaffold did not bare on base plates or a firm foundation. The tubular welded frame scaffold was erected on uneven concrete and wood shims. Observed on or about 29 January 2016.
Recent events (1)
- — Z (S) $2000
1926.416 E01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Jobsite - Employees were exposed to electrical shock hazards from frayed live electrical wiring protruding from a Red Arc Welding machine. Observed on or about 29 January 2016.
Recent events (1)
- — Z (S) $1600
1926.350 A09
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.350(a)(9): Compressed gas cylinder(s) were not secured in an upright position: a) Jobsite - Employees were exposed to explosion hazards of combustible materiel from improperly stored welding gasses. Observed on or about 29 January 2016.
Recent events (1)
- — Z (S) $2000
1926.403 B02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification. a) Jobsite - Employees were exposed to shock hazards from job made electrical extension cords that were not installed according to the instruction included in the listing and labeling. Extension cord was used to power a Red Arc Welder. Observed on or about 29 January 2016.
Recent events (1)
- — Z (S) $1200
More inspections at HUA DA CONSTRUCTION INC.
PHILADELPHIA, PA—2018-08-17 00:00:00
HUA DA CONSTRUCTION, INC.
PHILADELPHIA, PA—2017-10-19 00:00:00
HUA DA CONSTRUCTION, INC.
PHILADELPHIA, PA—2016-06-10 00:00:00
HUA DA CONSTRUCTION INC.
PHILADELPHIA, PA—2016-03-25 00:00:00
HUA DA CONSTRUCTION INC.
PHILADELPHIA, PA—2016-03-07 00:00:00
HUA DA CONSTRUCTION, INC.
View HUA DA CONSTRUCTION INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236116)
PLAIN CITY, OH—2026-07-09
RUSCILLI CONSTRUCTION
IRVINE, CA—2026-07-09
TOLL BROTHERS INC.
ROSEVILLE, CA—2026-07-09
JERRY LEE STAIRS INC.
NEWPORT, RI—2026-07-08
PEZZUCO CONSTRUCTION INC.
EVANSVILLE, IN—2026-07-08
L & J CONSTRUCTORS, LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341214583.