MUNDELEIN, IL ·
OSHA Inspection: ROLLOMATIC, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ROLLOMATIC, INC. in 1295 ARMOUR, MUNDELEIN, IL 60060 (NAICS 811310). OSHA activity number 341217016.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROLLOMATIC, INC.
- Site address
- 1295 ARMOUR
- City
- MUNDELEIN
- State
- IL
- ZIP
- 60060
- Mailing
- 1295 ARMOUR, MUNDELEIN, IL 60060
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 18
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.178 L02 II
- Issued
- Feb 17, 2016
- Abate by
- Mar 14, 2016
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace: a) Warehouse- The employer did not ensure that all employee(s) who operate the powered industrial vehicles were properly trained, evaluated, and certified to perform tasks in a safe manner.
Recent events (1)
- · Z (S) $1600
1910.22 D01
- Issued
- Feb 17, 2016
- Abate by
- Mar 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: a) Warehouse- The above mezzanine storage area did not have a marked load capacity plate. Trade show equipment, including signs, material, and small equipment were stored on top of the mezzanine over the temporary work shop area.
Recent events (1)
- · Z (O) $0
More inspections at Rollomatic, INC.
View Rollomatic, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811310)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341217016.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.