CAMBRIDGE, OH —
OSHA Inspection: FEDERAL-MOGUL IGNITION COMPANY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of FEDERAL-MOGUL IGNITION COMPANY in 6420 JOHN GLEN HWY, CAMBRIDGE, OH 43725 (NAICS 336399). OSHA activity number 341218089.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FEDERAL-MOGUL IGNITION COMPANY
- Site address
- 6420 JOHN GLEN HWY
- City
- CAMBRIDGE
- State
- OH
- ZIP
- 43725
- Mailing
- 6420 JOHN GLEN HWY, CAMBRIDGE, OH 43725
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336399
- Employees
- 200
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jun 1, 2016
- Abate by
- Aug 8, 2016
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees that were exposed to fire hazards from inappropriately installed exhaust and ventilation systems for two production kilns. a. On or about January 29, 2016, in the Pac-9 area at the workplace, employees operated two Watkins-Johnson production kilns that had inappropriately installed and constructed exhaust and ventilation systems. The PVC flex self supporting ventilation ducting was not designed for high temperature environments. The Grizzly Industrial dust collector impeller units were not constructed or designed to be used for the evacuation of high temperature gasses exiting the production kilns.
Recent events (2)
- — I (S) $4900
- — Z (S) $7000
More inspections at Federal-Mogul Ignition Company
View Federal-Mogul Ignition Company's full OSHA safety record →
More inspections in this industry (NAICS 336399)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341218089.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.