Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-02

OSHA Inspection: NOAA NW FISHERIES SCIENCE CENTER MUKILTEO RESEARCH STATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NOAA NW FISHERIES SCIENCE CENTER MUKILTEO RESEARCH STATION in 10 PARK AVENUE, MUKILTEO, WA 98275 (NAICS 541990). OSHA activity number 341220440.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Noaa NW Fisheries Science Center Mukilteo Research Station for free Get an email when a new federal OSHA severe-injury report for Noaa NW Fisheries Science Center Mukilteo Research Station is published. One employer, no account, unsubscribe in one click.
Site address
10 PARK AVENUE
City
MUKILTEO
State
WA
ZIP
98275
Mailing
2725 MONTLAKE BLVD E, SEATTLE, WA 98112
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541990
Employees
6
Ownership type
D

11 citations on file for this inspection.

1910.22 D01

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 25, 2016
Abate by
Apr 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:  a)       Metal Shop:  Aluminum and PVC pipes were stored on wooden rafters above the employees work area, exposing employees to possible struck by hazards.
Recent events (1)
  • · Z (S) $0

1910.23 A02

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 25, 2016
Abate by
Apr 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening:  a)       The Salmon Shed Head Tank was attached to a platform which was approximately 12 feet high.  The ladderway opening did not have a swing gate or a standard railing to prevent employees from falls.
Recent events (1)
  • · Z (S) $0

1910.23 D01

Serious Gravity 1 1 instance 8 exposed
Issued
Mar 25, 2016
Abate by
Apr 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(d)(1): The employer did not ensure that every flight of stairs having 4 or more risers was equipped with standard stair railings or standard handrails.  a)       Rear Deck;  A stairway with four risers measuring 39 inches wide was missing a standard stair railing on one side, exposing employees to potential fall hazards.
Recent events (1)
  • · Z (S) $0

1910.23 E01

Serious Gravity 1 1 instance 8 exposed
Issued
Mar 25, 2016
Abate by
Apr 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:  a)       The rear exit was equipped with a guardrail measuring 30 inches high with no midrail, exposing employees to potential fall hazards.
Recent events (1)
  • · Z (S) $0

1910.23 E02

Serious Gravity 1 1 instance 8 exposed
Issued
Mar 25, 2016
Abate by
Apr 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(2): Stair rails did not consist of a top rail, intermediate rail and/or posts, with the vertical height not more than 34 inches (86.36 cm) nor less than 30 inches (76.2 cm) from upper surface of top rail to surface of tread:   a)  The rear exit doors stair rail measured 29-31 inches high with no midrail or posts, exposing employees to potential fall hazards.
Recent events (1)
  • · Z (S) $0

1910.36 G02

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 25, 2016
Abate by
Apr 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:   a)      The aisleway between the Metal Shop and the Electrical Shop measured 18 inches wide because metal pipes/ rods were stored in the aisleway, exposing employees to potential tripping hazards.
Recent events (1)
  • · Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 25, 2016
Abate by
Apr 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a)  Electrical Shop: A knockout was missing on the electrical panel, exposing employees to potential electrical shock hazards.
Recent events (1)
  • · Z (S) $0

1910.303 G01 II

Repeat 1 instance 3 exposed
Issued
Mar 25, 2016
Abate by
Apr 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a)       Electrical Shop;  Metal pump housing units were stored underneath the breaker panel.  NOAA was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 906829, citation number 2, item number 5and was affirmed as a final order on July 23, 2013, with respect to a workplace located at Pasco, Washington.
Recent events (1)
  • · Z (R) $0

1910.213 S06

Other-than-serious 1 instance 2 exposed
Issued
Mar 25, 2016
Abate by
Apr 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards:  a)      Wood Shop;  There was sawdust around and under the Grizzly tablesaw (model no. G1022Z, serial no. 067542).  b)      Metal Shop;  There was sawdust and PVC dust around and under the Ridgid cut off saw (no. MS1065LZA).
Recent events (1)
  • · Z (O) $0

1910.253 B04 III

Other-than-serious 1 instance 2 exposed
Issued
Mar 25, 2016
Abate by
Apr 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour:  a)       Metal Shop, South Wall;  Oxygen and acetylene compressed gas cylinders were stored side by side with caps on.
Recent events (1)
  • · Z (O) $0

1910.334 A02 II

Other-than-serious 1 instance 2 exposed
Issued
Mar 25, 2016
Abate by
Apr 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:  a)       Metal Shop;  The yellow hanging plastic handy box (used to power the Dayton grinder) was cracked on top.
Recent events (1)
  • · Z (O) $0

View Noaa NW Fisheries Science Center Mukilteo Research Station's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341220440.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.