OSHA Inspection: THE GRAND BUILDER GROUP, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE GRAND BUILDER GROUP, INC in 145 LUDLOW ST, NEW YORK CITY, NY 10259 (NAICS 236220). OSHA activity number 341222644.

Watch THE Grand Builder Group, INC — free Get an email when a new federal OSHA severe-injury report for THE Grand Builder Group, INC is published. One employer, no account, unsubscribe in one click.
Site address
145 LUDLOW ST
City
NEW YORK CITY
State
NY
ZIP
10259
Mailing
2347 W. 13TH ST., BROOKLYN, NY 11223
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
23
Ownership type
A

3 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2250.00 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification.    a) 145 Ludlow St, Manhattan, NY, 1st floor, On or about 1/26/16: A 4 gang receptacle enclosure, meant to be permanently affixed to a structure, was used as a receptacle for an extension cord.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $2800

1926.405 D

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $4000.00 Reduced
29 CFR 1926.405(d): Panelboards mounted in cabinets, cutout boxes or enclosures designed for the purpose were not dead front:    29 CFR 1926.405(d): Panelboards mounted in cabinets, cutout boxes or enclosures designed for the purpose were not dead front.    154 Ludlow St, Manhattan, NY, Power,  Panelboard cabinet. On or about 1/26/16: A power panel cabinet was not secured or dead front exposing employees  to live conductors.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4900

1926.405 J01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $0.00 Reduced
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact.    a) 145 Ludlow St, Manhattan, NY, 1st floor, On or about 1/26/16: An extension cord contained a 2 gang receptacle that was not enclosed in an approved enclosure.