Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRI STAR CONSTRUCTION GROUP, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TRI STAR CONSTRUCTION GROUP, INC in 190 BOWERY ST, NEW YORK, NY 10026 (NAICS 236220). OSHA activity number 341222768.

Watch TRI Star Construction Group, INC — free Get an email when a new federal OSHA severe-injury report for TRI Star Construction Group, INC is published. One employer, no account, unsubscribe in one click.
Site address
190 BOWERY ST
City
NEW YORK
State
NY
ZIP
10026
Mailing
770 LEXINGTON AVE, NEW YORK, NY 10065
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
25
Ownership type
A

3 citations on file for this inspection.

1926.403 E

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 4, 2016
Abate by
Apr 12, 2016
Penalty
Initial $6,300 · Current $6,300
29 CFR 1926.403(e): All splices and joints and free ends of conductors were not covered with insulation equivalent to that of the conductors or with an insulating device designed for the purpose.  a) 190 Bowery St, Manhattan, NY, Temporary Lighting circuit. On or about 1/27/16: Wiring used as a temporary lighting circuit contained splices that used black electrical tape as insulation which was not equivalent to the original insulation properties.
Recent events (1)
  • — Z (S) $6300

1926.405 A02 II C

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 4, 2016
Abate by
Apr 12, 2016
Penalty
Initial $4,500 · Current $4,500
29 CFR 1926.405(a)(2)(ii)(C): Receptacles for uses other than temporary lighting were installed on branch circuits which supplied temporary lighting.   a) 190 Bowery St, Manhattan, NY, Temporary wiring circuit, On or about 1/27/16: Receptacles were installed on the temporary lighting wiring to power cord connected equipment.
Recent events (1)
  • — Z (S) $4500

1926.405 G02 IV

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 4, 2016
Abate by
Apr 14, 2016
Penalty
Initial $4,500 · Current $4,500
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.  a. 190 Bowery St, New York, NY  Employees throughout the jobsite were observed engaged in construction activities in areas where flexible cords were used without any means of strain relief exposing employee(s) to electrical shock hazards.
Recent events (1)
  • — Z (S) $4500

View TRI Star Construction Group, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341222768.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.