CEDARTOWN, GA —
OSHA Inspection: DEAN STEEL BUILDINGS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DEAN STEEL BUILDINGS, INC. in 500 TENTH STREET, CEDARTOWN, GA 30125 (NAICS 332312). OSHA activity number 341225985.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DEAN STEEL BUILDINGS, INC.
- Site address
- 500 TENTH STREET
- City
- CEDARTOWN
- State
- GA
- ZIP
- 30125
- Mailing
- 500 TENTH STREET, CEDARTOWN, GA 30125
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 19
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Apr 25, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Main building: The Niagara Shear did not have the guard adjusted to protect the operator and other employees from hazards such as those created by point of operation, causing a caught-in hazard. (b) Main building: The Sebastian Lathe did not have a guard on it to prevent chips from flying towards the employee causing a struck-by and caught-in hazard. (c) Main building: The MSC mill did not have a guard on it to prevent chips from flying towards the employee causing a struck-by hazard.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.212 B
- Issued
- Apr 25, 2016
- Abate by
- May 18, 2016
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) Main building: The MSC was not secured to the floor to prevent tipping over causing a struck-by hazard.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
More inspections at Dean Steel Buildings, INC.
View Dean Steel Buildings, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341225985.