MILFORD, CT —
OSHA Inspection: UNITED ELECTRIC CONTROLS PRECISION SENSORS DIVISIONS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UNITED ELECTRIC CONTROLS PRECISION SENSORS DIVISIONS in 50 SEEMANS LANE, MILFORD, CT 06460 (NAICS 334513). OSHA activity number 341227577.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED ELECTRIC CONTROLS PRECISION SENSORS DIVISIONS
- Site address
- 50 SEEMANS LANE
- City
- MILFORD
- State
- CT
- ZIP
- 06460
- Mailing
- 50 SEEMANS LANE, MILFORD, CT 06460
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334513
- Employees
- 65
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.147 C01
- Issued
- Mar 14, 2016
- Penalty
- Initial $6,300 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. WORKSHOP: The employer had not established and implemented a site specific hazardous energy control lockout/tagout program consisting of machine specific step-by-step written energy control procedures and employee training for the employees during servicing and maintenance of equipment, such as (but not limited to) the CNC lathes and millers. ABATED DURING THE INSPECTION
Recent events (2)
- — I (S) $3150
- — Z (S) $6300
1910.147 C04 I
- Issued
- Mar 14, 2016
- Abate by
- Apr 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. WORKSHOP: The employer had not established and implemented written step-by-step energy control procedures in the machine specific for the employees during servicing and maintenance of equipment, such as (but not limited to) the CNC lathes and millers.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Mar 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the WORKSHOP: The employees, as "authorized, affected and other" types were not provided with training and information in the controlling of potentially hazardous and unexpected releases of energy sources (lo/to) during servicing and maintenance of equipment, such as (but not limited to) the CNC lathe and millers. ABATED DURING THE INSPECTION
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Mar 14, 2016
- Penalty
- Initial $3,600 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. WORKSHOP: 1. The rotating shaft of the Hardinge lathe was unguarded. ABATED DURING THE INSPECTION 2. The left side unused portion of the saw blade of the MSC Metal Cutting bandsaw blade was unguarded. ABATED DURING THE INSPECTION
Recent events (2)
- — I (S) $1800
- — Z (S) $3600
1910.219 C04 I
- Issued
- Mar 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(I): Projecting shaft ends. Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves: WORKSHOP: The shaft ends and nuts of the Powermatic grinder/buffer were unguarded. ABATED DURING THE INSPECTION
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Mar 14, 2016
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. WORKSHOP: The point-of-operation of the Enerpac 642, hydraulic press was unguarded. ABATED DURING THE INSPECTION
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
1910.1200 E01
- Issued
- Mar 14, 2016
- Penalty
- Initial $3,600 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following: WORKSHOP: The employer had not established and implemented a written hazard communication program, including the Globalized Harmonized System where employees were required to work with chemicals, such as (but not limited to) methyl ethyl ketone, alcohol, oils, greases, and coolants. ABATED DURING THE INSPECION
Recent events (2)
- — I (S) $1800
- — Z (S) $3600
1910.1200 H01
- Issued
- Mar 14, 2016
- Abate by
- Apr 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets. WORKSHOP: The employees who were required to work with chemicals, such as (but not limited to) methyl ethyl ketone, alcohol, oils, greases, and coolants were not provided with training and information in the hazard communication program, including the Globalized Harmonized System.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D02
- Issued
- Mar 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. WORKSHOP: The employer had not verified through a written certification that the workplace hazard assessment for personal protective equipment (PPE) had been performed and completed. ABATED DURING THE INSPECTION
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 334513)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341227577.