Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROGER B. KENNEDY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROGER B. KENNEDY, INC. in 9932 GRAND LAKES BLVD, ORLANDO, FL 32827 (NAICS 236116). OSHA activity number 341228120.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Roger B. Kennedy, INC. — free Get an email when a new federal OSHA severe-injury report for Roger B. Kennedy, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9932 GRAND LAKES BLVD
City
ORLANDO
State
FL
ZIP
32827
Mailing
1105 KENSINGTON PARK DRIVE, ALTAMONTE SPRINGS, FL 32714
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 3 instances 50 exposed
Issued
Feb 19, 2016
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a. Building 1 and building 3, during progress of work at the second, third and fourth floor balconies, railing were removed and not replaced, exposing employees to a fall hazard, on or about 02/04/2016.   b. Building 1 fourth floor, the top rail at the elevator shaft was removed and not replaced, exposing employees to a fall hazard, on or about 02/04/2016.   c. Building 1 third and fourth floor porch at the west side, an employee was exposed to a fall hazard during guardrail installation, on or about 02/04/2016.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1926.405 A02 II E

Other-than-serious 1 instance 30 exposed
Issued
Feb 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:   a. Building 1, employees were exposed to an electrical hazard, in that, lamps used in temporary wiring for general illumination were not equipped with casing to protect them from damage, on or about 02/04/2016.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 A02 II F

Other-than-serious 1 instance 30 exposed
Issued
Feb 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(F): Temporary lights were suspended by their electric cords when such lights and cords were not designed for suspension:   a. Building 1, employees were exposed to an electrical hazard, in that, lamps used in temporary wiring for general illumination were suspended by the conductors, on or about 02/04/2016.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Roger B. Kennedy, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341228120.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.