Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JKA ROOFING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JKA ROOFING LLC in 7756 SCIOTO CT, WEST CHESTER, OH 45069 (NAICS 238160). OSHA activity number 341230662.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JKA Roofing LLC — free Get an email when a new federal OSHA severe-injury report for JKA Roofing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JKA ROOFING LLC
Site address
7756 SCIOTO CT
City
WEST CHESTER
State
OH
ZIP
45069
Mailing
828 CREVIS LANE, COLUMBUS, OH 43228
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 10, 2016
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.    Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    Located on the south side of a residential low pitch roof structure, employees were observed removing shingles while not utilizing any fall protection system. Potential fall height was measured in excess of 25' with a roof pitch of 4 in 12.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

View JKA Roofing LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341230662.