COLUMBUS, OH ·
OSHA Inspection: QUAD GRAPHICS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of QUAD GRAPHICS in 4051 FONDORF DRIVE, COLUMBUS, OH 43228 (NAICS 323111). OSHA activity number 341231942.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUAD GRAPHICS
- Site address
- 4051 FONDORF DRIVE
- City
- COLUMBUS
- State
- OH
- ZIP
- 43228
- Mailing
- 4051 FONDORF DRIVE, COLUMBUS, OH 43228
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 100
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jun 22, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $6,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. a. At the workplace, the employer did not develop, document or utilize procedures for the control of potentially hazardous energy when employees were clearing web jams and feeding paper webs into the N012 Harris Printing Press.
Recent events (3)
- · F (S) $0
- · C (S) $6000
- · Z (S) $6000
1910.147 C04 II D
- Issued
- Jun 22, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 29 CFR 1910.147(c)(4)(ii)(D): Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. a. At the workplace in the N012 area, the employer's lockout procedures for the N012 Enkel Splicer did not include a method to verify isolation and control of pneumatic energy of the N012 Enkel Splicer. The employer's procedures did not include instructions such as checking pressure gauges or bleeding of pneumatic lines.
Recent events (3)
- · F (S) $0
- · C (S) $5000
- · Z (S) $5000
More inspections at Quad Graphics
View Quad Graphics's full OSHA safety record →
More inspections in this industry (NAICS 323111)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341231942.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.