NAPERVILLE, IL —
OSHA Inspection: STEC ROOFING S&G, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STEC ROOFING S&G, INC. in 3 N. WEST ST., NAPERVILLE, IL 60564 (NAICS 238160). OSHA activity number 341233765.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STEC ROOFING S&G, INC.
- Site address
- 3 N. WEST ST.
- City
- NAPERVILLE
- State
- IL
- ZIP
- 60564
- Mailing
- 271 BURLINGTON AVE., NAPERVILLE, IL 60564
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1903.19 D01
- Issued
- May 17, 2016
- Abate by
- Jul 5, 2016
- Penalty
- Initial $400 · Current $0 Reduced
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. Stec Roofing S&G, Inc., failed to submit documents to OSHA verifying that each of the following cited violations had been corrected: Citation Number Item Number Abatement Date 01 03 02/26/2016
Recent events (2)
- — I (O) $0
- — Z (O) $400
1926.100 A
- Issued
- Feb 16, 2016
- Abate by
- Feb 26, 2016
- Penalty
- Initial $1,600 · Current $640 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. Employees performing residential roofing operations were exposed to struck by hazards while employees handed roofing material to the second level from the first level. The employer failed to mandate the use of hard hats. Abatement certification is required of this item in accordance with requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $640
- — Z (S) $1600
1926.102 A01
- Issued
- Feb 16, 2016
- Abate by
- Feb 26, 2016
- Penalty
- Initial $1,600 · Current $640 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents. Employees performing installation of roofing material on a residential single family home with a pneumatic nail fastener were exposed to struck by hazards when the employer failed to ensure the use of eye protection. Abatement certification is required of this item in accordance with requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $640
- — Z (S) $1600
1926.501 B13
- Issued
- Feb 16, 2016
- Abate by
- Feb 26, 2016
- Penalty
- Initial $2,800 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Employees performing residential roofing operations were exposed to a 12.5 foot fall when the employer failed to ensure that fall protection was utilized. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $1120
- — Z (S) $2800
1926.1053 B01
- Issued
- Feb 16, 2016
- Abate by
- Feb 26, 2016
- Penalty
- Initial $2,800 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. Employees performing residential roofing operations were exposed to a 13 foot fall when the employer failed to ensure the extension ladder used extended at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $1120
- — Z (S) $2800
More inspections at Stec Roofing S&G, INC.