EXETER, NH ·
OSHA Inspection: CONTINENTAL MICROWAVE AND TOOL CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CONTINENTAL MICROWAVE AND TOOL CO., INC. in 11 CONTINENTAL DRIVE, EXETER, NH 03833 (NAICS 334419). OSHA activity number 341242295.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONTINENTAL MICROWAVE AND TOOL CO., INC.
- Site address
- 11 CONTINENTAL DRIVE
- City
- EXETER
- State
- NH
- ZIP
- 03833
- Mailing
- 11 CONTINENTAL DRIVE, EXETER, NH 03833
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334419
- Employees
- 420
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 C06 I
- Issued
- Mar 10, 2016
- Abate by
- Mar 16, 2016
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. Site - The employer did not conduct periodic inspections to ensure that the procedures in their own lockout/tagout program met the requirement of the standard and were being followed.
Recent events (2)
- · I (S) $2500
- · Z (S) $5000
1910.147 C06 II
- Issued
- Mar 10, 2016
- Abate by
- Mar 16, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a. Site - The employer did not certify that periodic inspections, at least annually, had been performed.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C07 I
- Issued
- Mar 10, 2016
- Abate by
- Mar 16, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a. Site - Not all of the employees who were performing lockout/tagout on machinery for maintenance purposes were provided with training by the employer.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C08
- Issued
- Mar 10, 2016
- Abate by
- Mar 16, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(8): Lockout or tagout was not performed only by the authorized employees who are performing the servicing or maintenance: a. Site - Employees who were not designated as authorized employees were performing lockout/tagout on machinery for maintenance purposes.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 334419)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341242295.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.