NEWPORT NEWS, VA —
OSHA Inspection: DAVIS BOAT WORKS, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of DAVIS BOAT WORKS, INC. in 99 JEFFERSON AVENUE, NEWPORT NEWS, VA 23607 (NAICS 336611). OSHA activity number 341245801.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAVIS BOAT WORKS, INC.
- Site address
- 99 JEFFERSON AVENUE
- City
- NEWPORT NEWS
- State
- VA
- ZIP
- 23607
- Mailing
- 99 JEFFERSON AVENUE, NEWPORT NEWS, VA 23607
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 80
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.212 A05
- Issued
- Jul 18, 2016
- Abate by
- Aug 11, 2016
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: a. Date of Violation: On or about 02-11-2016 and times prior thereto, located at Davis Boat Works, Inc., 99 Jefferson Avenue Newport News, VA 23607 onboard naval berthing barge, employee(s) were exposed to ineffectively guarded fan blades on an Allegro Ventilation fan located below deck. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.304 G05
- Issued
- Jul 18, 2016
- Abate by
- Aug 11, 2016
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: Instance #1: Date of Violation: On or about 02-11-2016 and times prior thereto, located at Davis Boat Works, Inc., 99 Jefferson Avenue Newport News, VA 23607, employee(s) were exposed to electrical shock hazards from a "drop-light" that had missing grounding pins and was not effectively grounded. Instance #2: Date of Violation: On or about 02-11-2016 and times prior thereto, located at Davis Boat Works, Inc., 99 Jefferson Avenue Newport News, VA 23607, employee(s) were exposed to electrical hazards from a ventilation fan used below deck that had a missing ground pin and was not effectively grounded. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.305 G01 IV B
- Issued
- Jul 18, 2016
- Abate by
- Aug 11, 2016
- Penalty
- Initial $2,100 · Current $1,575 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables were used: Where run through holes in walls, ceilings, or floors; a. Date of Violation: On or about 02-11-2016 and times prior thereto, located at Davis Boat Works, Inc., 99 Jefferson Avenue Newport News, VA 23607, located inside the spray painting building, employee(s) were exposed to electrical hazards from a temporary 50 foot extension cord that was plugged into an inside receptacle and passed through a hole in the concrete block wall leading to the outside of the building. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1575
- — Z (S) $2100
1910.305 G01 IV C
- Issued
- Jul 18, 2016
- Abate by
- Aug 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: Where run through doorways, windows, or similar openings: Instance #1: Date of Violation: On or about 02-11-2016 and times prior thereto, located at Davis Boat Works, Inc., 99 Jefferson Avenue Newport News, VA 23607, in a shore side building near the brow of barge being worked on, employees were exposed to fire and electrical hazards from a 50 foot extension cord that was run through a personnel entry door opening whereas the door opened and closed down on the cord as it went out towards the outside gravel area to supply power to a handheld portable grinder. The cord had obvious pinched deformities. Instance #2: Date of Violation: On or about 02-11-2016 and times prior thereto, located at Davis Boat Works, Inc., 99 Jefferson Avenue Newport News, VA 23607, employee(s) were exposed to electrical hazards from welding cables passing through the water-tight hatch door on the naval berthing barge. The cables had obvious pinch deformities with exposed conductor wires. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Jul 18, 2016
- Abate by
- Aug 11, 2016
- Penalty
- Initial $2,100 · Current $1,575 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cord and cable was not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws. Instance #1: Date of Violation: On or about 02-11-2016 and times prior thereto, located at Davis Boat Works, Inc., 99 Jefferson Avenue Newport News, VA 23607, onboard the naval berthing barge, employees were exposed to electrical hazards from a 50 foot extension cord that did not have any strain relief on the female end of the plug. The cord provided power to a Dewalt brand DWE402 41/2 inch angle grinder. Instance #2: Date of Violation: On or about 02-11-2016 and times prior thereto, located at Davis Boat Works, Inc., 99 Jefferson Avenue Newport News, VA 23607, onboard the naval berthing barge, employees were exposed to electrical hazards from a ventilation fan that had missing strain relief where the electrical supply cord entered the fan housing unit. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1575
- — Z (S) $2100
1915.56 B02
- Issued
- Jul 18, 2016
- Abate by
- Aug 11, 2016
- Penalty
- Initial $4,900 · Current $3,675 Reduced
General-duty citation text
29 CFR 1915.56(b)(2): Welding cable was not free from repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected. (a) Date of Violation: On or about 02-11-2016 and times prior thereto, located at Davis Boat Works, Inc., 99 Jefferson Avenue Newport News, VA 23607, on the main deck, starboard side forward space engineering room, an employee was exposed to a stick welder with a damaged area of cable with exposed electrical conductors covered by electrical tape within 1 inch of the electrode holder. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3675
- — Z (S) $4900
1915.73 D
- Issued
- Jul 18, 2016
- Abate by
- Aug 11, 2016
- Penalty
- Initial $3,500 · Current $2,625 Reduced
General-duty citation text
29 CFR 1915.73(d): When employees were exposed to unguarded edges of decks, platforms, flats, or similar flat surfaces, more than 5 feet above a solid surface, the edges were not guarded by adequate guardrails meeting the requirements of 29 CFR 1915.71(j)(1). (a) Date of Violation: On or about 02-11-2016 and times prior thereto, located at Davis Boat Works, Inc., 99 Jefferson Avenue Newport News, VA 23607, onboard a dry-docked pleasure craft on stilts landside, employee(s) were exposed to a fall hazard from approximately 7 feet at an unguarded 32 inch wide opening to the gravel/rock surface below. The bulkhead door was affixed and tied in the open position. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2625
- — Z (S) $3500
More inspections at Davis Boat Works, INC.
View Davis Boat Works, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341245801.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.