NEW YORK, NY —
OSHA Inspection: V & P PAINTING LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of V & P PAINTING LLC in 453 BROOME STREET, NEW YORK, NY 10013 (NAICS 238310). OSHA activity number 341246536.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- V & P PAINTING LLC
- Site address
- 453 BROOME STREET
- City
- NEW YORK
- State
- NY
- ZIP
- 10013
- Mailing
- 801 SOUTH STREET, ELIZABETH, NJ 07202
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.20 B02
- Issued
- Mar 31, 2016
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not ensure that frequent and regular inspections of the job sites, materials, and equipment were conducted by a competent person: a) On or about 2/10/16 at a renovation project located at 453 Broome Street, New York, New York; frequent and regular inspections were not completed to evaluate work conditions and methods to ensure that employees were protected from fall hazards, struck-by hazards, fire hazards, and electrical hazards. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — C (S) $2000
- — F (S) $2000
- — Z (S) $2000
1926.403 B02
- Issued
- Mar 31, 2016
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about 2/10/16 at a renovation project located at 453 Broome Street, New York, New York; employees were using a re-locatable power tap (power strip) for power to portable tools. The re-locatable power tap is not listed for use in construction. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — C (S) $2000
- — F (S) $2000
- — Z (S) $2000
1926.404 B01 I
- Issued
- Mar 31, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) On or about 2/10/16 at a renovation project located at 453 Broome Street, New York, New York; employees were using screw guns and spiral saws to install drywall on the 1st floor. The tools were plugged into a re-locatable power tap that was connected to an extension cord. The employee(s) were not using ground fault circuit interrupters or an assured equipment grounding conductor program. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — C (S) $1200
- — F (S) $1200
- — Z (S) $1200
1926.416 E01
- Issued
- Mar 31, 2016
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) On or about 2/10/16 at a renovation project located at 453 Broome Street, New York, New York; employees were using an extension cords that had damaged jackets. Damaged/worn cords were spliced together with other cords and equipment including but not limited to a re-locatable power tap. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — C (S) $2000
- — F (S) $2000
- — Z (S) $2000
1926.451 C02
- Issued
- Mar 31, 2016
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) On or about 2/10/16 at a renovation project located at 453 Broome Street, New York, New York; employees were using a welded frame scaffold to place drywall on the ceiling over a stairwell. The scaffold did not have base plates for each of the legs. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — C (S) $2000
- — F (S) $2000
- — Z (S) $2000
1926.451 C02 I
- Issued
- Mar 31, 2016
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement: a) On or about 2/10/16 at a renovation project located at 453 Broome Street, New York, New York; employees were using a welded frame scaffold to place drywall on the ceiling over a stairwell. The scaffold was placed on scaffold planks that were resting on a brick ledge over the stairwell. The planks were not secured against movement or displacement. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — C (S) $2000
- — F (S) $2000
- — Z (S) $2000
More inspections in this industry (NAICS 238310)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341246536.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.