Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AZZ GALVANIZING-SAN ANTONIO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AZZ GALVANIZING-SAN ANTONIO in 5731 FM 1346, SAN ANTONIO, TX 78220 (NAICS 332812). OSHA activity number 341246684.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AZZ Galvanizing-San Antonio — free Get an email when a new federal OSHA severe-injury report for AZZ Galvanizing-San Antonio is published. One employer, no account, unsubscribe in one click.
Site address
5731 FM 1346
City
SAN ANTONIO
State
TX
ZIP
78220
Mailing
5731 FM 1346, SAN ANTONIO, TX 78220
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
65
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 1 instance 30 exposed
Issued
May 27, 2016
Abate by
Jun 12, 2016
Penalty
Initial $4,000 · Current $0 Reduced
OSH ACT of 1970 Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to thermal burns:   On or about February 11, 2016, employees were exposed to thermal burn hazards, while walking and working near a Pyrotek Metaullics Zinkoff Recovery System, which was not guarded to prevent contact.
Recent events (3)
  • — F (S) $0
  • — C (S) $4000
  • — Z (S) $4000

1910.23 C01

Serious Gravity 1 1 instance 3 exposed
Issued
May 27, 2016
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toe boards:  Work yard: On or about February 11, 2016, and at times prior thereto, an employee was exposed to fall hazards greater than 4 feet to the paved ground below, while working from a steel kettle that did not have guardrails installed.
Recent events (3)
  • — F (S) $3000
  • — C (S) $3000
  • — Z (S) $3000

1910.176 B

Serious Gravity 10 1 instance 2 exposed
Issued
May 27, 2016
Abate by
Jun 17, 2016
Penalty
Initial $7,000 · Current $4,700 Reduced
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:    Receiving Area: On or about March 3, 2016 and at times prior thereto, employees were exposed to struck-by hazards, when unloading I-beams from a stack, while the I-beams were not secured to prevent tipping over.
Recent events (3)
  • — F (S) $4700
  • — C (S) $7000
  • — Z (S) $7000

1910.305 B01 I

Serious Gravity 5 2 instances 40 exposed
Issued
May 27, 2016
Abate by
Jun 12, 2016
Penalty
Initial $6,000 · Current $4,100 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed:     a) Break Room Hall Way: On or about February 11, 2016 and at times prior thereto, employees were exposed to electrical hazards, while walking near an electrical cabinet exposing 220 volt electrical conductors.    b) Shop Area; Eastside wall: On or about February 11, 2016 and at times prior thereto, employees were exposed to electrical hazards, while working near an outlet box exposing 120 volt electrical conductors.
Recent events (3)
  • — F (S) $4100
  • — C (S) $6000
  • — Z (S) $6000

1910.305 B02 I

Serious Gravity 10 2 instances 10 exposed
Issued
May 27, 2016
Penalty
Initial $7,000 · Current $4,700 Reduced
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose.  In completed installations, each outlet box did not have a cover, faceplate, or fixture canopy:      a) Shop area; Westside wall: On or about February 11, 2016, and at times prior thereto, employees were exposed to electrical hazards while plugging in a portable radio to an outlet that had a missing cover plate exposing electrical conductors.         b) Shop Area; Westside wall: On or about February 11, 2016 and at times prior thereto, employees were exposed to electrical hazards while working near a cabinet with an open cover exposing electrical conductors.
Recent events (3)
  • — F (S) $4700
  • — C (S) $7000
  • — Z (S) $7000

1910.305 G01 IV

Serious Gravity 5 2 instances 65 exposed
Issued
May 27, 2016
Abate by
Jun 3, 2016
Penalty
Initial $6,000 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):     a) Shop Area; Westside wall: On or about February 11, 2016 and at times prior thereto, employees were exposed to electrical hazards, while using Milwaukee battery Chargers (Serial number: D63A9151986709G) that were plugged into an extension cord used as permanent wiring.          b) Shop Area; Eastside wall: On or about February 11, 2016 and at times prior thereto, employees were exposed to electrical hazards, while using a vending machine that had the power cord run through a wall hole, and was plugged into an outlet receptacle with exposed wires.
Recent events (3)
  • — F (S) $0
  • — C (S) $6000
  • — Z (S) $6000

1910.157 C01

Other-than-serious 1 instance 65 exposed
Issued
May 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   Shop Area; Eastside passage way: On or about February 11, 2016, and at times prior thereto, employees were exposed to fire hazards in the event of an emergency, while the fire extinguisher was on the ground and not mounted in the designated area.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View AZZ Galvanizing-San Antonio's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341246684.