WALDOBORO, ME ·
OSHA Inspection: FLAME GRILLING PRODUCTS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FLAME GRILLING PRODUCTS, INC. in 2500 WINSLOWS MILLS ROAD, WALDOBORO, ME 04572 (NAICS 321999). OSHA activity number 341253789.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLAME GRILLING PRODUCTS, INC.
- Site address
- 2500 WINSLOWS MILLS ROAD
- City
- WALDOBORO
- State
- ME
- ZIP
- 04572
- Mailing
- 2500 WINSLOWS MILLS ROAD, WALDOBORO, ME 04572
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 10
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- Feb 23, 2016
- Abate by
- Feb 29, 2016
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: Basement - Sawdust, wood chips and slabs had accumulated on the floor for several work shifts.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.23 D01 III
- Issued
- Feb 23, 2016
- Abate by
- Feb 29, 2016
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side: Stairway between Break Room and Basement - A stair railing was not provided on the left side descending. A mid rail was not provided on the right side descending.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1910.157 C01
- Issued
- Feb 23, 2016
- Abate by
- Feb 29, 2016
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Basement, Wall adjacent to Planer - Access to the fire extinguisher was obstructed and the fire extinguisher location was not identified. b) Main Entry Area between Office and Packaging - The fire extinguisher location was not identified. c) Entryway from Packaging to Main Entry Area - The fire extinguisher location was not identified. d) Entryway from Packaging to Bulk Area - The fire extinguisher location was not identified. e) Basement, Bottom of Stairway - The fire extinguisher location was not identified.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.305 B02
- Issued
- Feb 23, 2016
- Abate by
- Feb 29, 2016
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, outlet boxes and fittings were not provided with covers approved for the purpose: In the following locations junction boxes and receptacle boxes were not provided with covers: a) Basement, Ceiling over a Porter Cable Planer - One junction box b) Basement, Ceiling over the Main Aisle - Five junction boxes c) Office - Two receptacle boxes
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.334 A01
- Issued
- Feb 23, 2016
- Abate by
- Feb 29, 2016
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.334(a)(1): Flexible electric cords were fastened with staples or otherwise hung in such a fashion as could damage the outer jacket or insulation: a) Basement, Wall Adjacent to Planer - A black extension cord was supported by metal pipe hangers that were used to support a sanitary sewer pipe. b) Basement, Wall Adjacent to Planer - The flexible cord of a receptacle box was supported by a metal pipe hanger that was used to support a sanitary sewer pipe.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
More inspections in this industry (NAICS 321999)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341253789.