Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACURLITE STRUCTURAL SKYLIGHTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACURLITE STRUCTURAL SKYLIGHTS, INC. in 1017 N. VINE ST.., BERWICK, PA 18603 (NAICS 332323). OSHA activity number 341255107.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Acurlite Structural Skylights, INC. — free Get an email when a new federal OSHA severe-injury report for Acurlite Structural Skylights, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1017 N. VINE ST..
City
BERWICK
State
PA
ZIP
18603
Mailing
1017 N. VINE ST., BERWICK, PA 18603
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
20
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 23, 2016
Penalty
Initial $1,700 · Current $1,700
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to ejection and crushing hazards from operating powered industrial trucks:   a) Production Area: Employees were exposed to ejection and crushing hazards while operating the Toyota 7425 propane forklift (model 42-3FG25, s/n 22382) which was not equipped with an operator restraint device (seatbelt) as observed on or about February 17, 2016.                                                                    CORRECTED DURING INSPECTION. ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $1700

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Mar 23, 2016
Penalty
Initial $1,020 · Current $0 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:        a) Production Area: A Handy metal electrical box located on the ground was being used to power personal items. Employees were exposed to electrical hazards, as observed on or about February 17, 2016.                                                                                             CORRECTED DURING INSPECTION. ABATEMENT CERTIFICATION REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1020

1910.147 C01

Other-than-serious 1 instance 6 exposed
Issued
Mar 23, 2016
Abate by
Apr 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a) At the facility: The employer did not establish a Lockout/Tagout Program consisting of energy control procedures, employee training and periodic inspections for the maintenance and servicing of equipment including but not limited to the 150-ton Baykal Fab-Line press brake, Elumatec SBZ 151 Profile Machine Center , and the Double-Header Miter Saw, on or about February 17, 2016.                                                                                              ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Acurlite Structural Skylights, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341255107.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.