Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: BOH ELECTRONICS, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BOH ELECTRONICS, INC in 230 MONROE STREET NORTH, HUDSON, WI 54016 (NAICS 334419). OSHA activity number 341258903.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BOH Electronics, INC for free Get an email when a new federal OSHA severe-injury report for BOH Electronics, INC is published. One employer, no account, unsubscribe in one click.
Site address
230 MONROE STREET NORTH
City
HUDSON
State
WI
ZIP
54016
Mailing
230 MONROE STREET NORTH, HUDSON, WI 54016
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334419
Employees
35
Ownership type
A

3 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 21, 2016
Abate by
May 19, 2016
Penalty
Initial $2,520 · Current $1,764 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  (a) BOH Electronics, receiving area; the employer did not train and evaluate the forklift operators to ensure they were competent to operate the forklift safely.
Recent events (2)
  • · I (S) $1764
  • · Z (S) $2520

1910.303 B02

Serious Gravity 1 1 instance 33 exposed
Issued
Apr 21, 2016
Abate by
May 19, 2016
Penalty
Initial $1,890 · Current $1,323 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Throughout the production areas; at the work stations power strips were mounted/installed and or linked in series in place of permanently installed wiring and electrical outlets.
Recent events (2)
  • · I (S) $1323
  • · Z (S) $1890

1910.1200 E01 I

Other-than-serious 1 instance 30 exposed
Issued
Apr 21, 2016
Abate by
May 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate safety data sheet:  (a) Throughout the facility; the employer did not develop and maintain a listing of the chemicals known to be used in the workplace.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View BOH Electronics, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341258903.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.