OSHA Inspection: A & B ELECTRIC COMPANY INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of A & B ELECTRIC COMPANY INC. in 164 JEANETTE PHILLIPS DRIVE, UNIVERSITY, MS 38677 (NAICS 238210). OSHA activity number 341261527.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & B Electric Company INC. — free Get an email when a new federal OSHA severe-injury report for A & B Electric Company INC. is published. One employer, no account, unsubscribe in one click.
Site address
164 JEANETTE PHILLIPS DRIVE
City
UNIVERSITY
State
MS
ZIP
38677
Mailing
P.O. BOX 1265, MERIDIAN, MS 39302
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
150
Ownership type
A

2 citations on file for this inspection.

1926.405 A02 II E

Other-than-serious 1 instance 1 exposed
Issued
Mar 2, 2016
Penalty
Initial $5,670 · Current $5,000 Reduced
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:    (a) South building 3rd floor right wing - On or about February 4, 2016 a strand of temporary lighting running from the ceiling to a temporary electrical power stand had one open socket sitting on the wood frame of the temporary electrical power stand exposing employees to the hazard of contacting live 120 volts.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $5670

1926.405 G01 II

Other-than-serious 30 instances 21 exposed
Issued
Mar 2, 2016
Abate by
Mar 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(1)(ii): Flexible cord was not equipped with an attachment plug and energized from a receptacle outlet when used as permitted in 29 CFR 1926.405(g)(1)(i) [C], [F], or [H]:  (a) North and South buildings throughout - On or about February 4, 2016 the temporary light cords had the factory plugged end removed and then the cord was hard wired to a switch for lighting control.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View A & B Electric Company INC.'s full OSHA safety record →