Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RYTEC CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of RYTEC CORPORATION in W223 N16601 CEDAR PARKWAY, JACKSON, WI 53037 (NAICS 326199). OSHA activity number 341263275.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rytec Corporation — free Get an email when a new federal OSHA severe-injury report for Rytec Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
RYTEC CORPORATION
Site address
W223 N16601 CEDAR PARKWAY
City
JACKSON
State
WI
ZIP
53037
Mailing
W223 N16601 CEDAR PARKWAY, JACKSON, WI 53037
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
175
Ownership type
A

2 citations on file for this inspection.

1910.134 I07

Serious Gravity 1 1 instance 3 exposed
Issued
May 12, 2016
Penalty
Initial $2,295 · Current $2,295

Hazardous substances 0560

29 CFR 1910.134(i)(7): Where only high-temperature alarms were used, the air supply was not monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10 ppm:  (a) The source of supplied air for respirators used by workers performing painting operations was an oil lubricated air compressor equipped with a high temperature alarm, but not equipped with a carbon monoxide alarm. The air supply was monitored for carbon monoxide at an annual frequency, which was not sufficient to assure that carbon monoxide levels would not exceed 10 ppm.
Recent events (2)
  • — I (S) $2295
  • — Z (S) $2295

1910.151 C

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
May 12, 2016
Penalty
Initial $3,825 · Current $0 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   (a) In the vicinity of the Wash Booth in the Painting Area, where a corrosive liquid (ChemKleen 163) was used by employees to clean metal parts, suitable facilities for quick drenching or flushing of the eyes were not provided within the work area for immediate emergency use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3825

View Rytec Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341263275.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.