OSHA Inspection: MAHLE BEHR DAYTON L.L.C.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MAHLE BEHR DAYTON L.L.C. in 1600 WEBSTER ST., DAYTON, OH 45404 (NAICS 336391). OSHA activity number 341266484.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mahle Behr Dayton L.L.C. — free Get an email when a new federal OSHA severe-injury report for Mahle Behr Dayton L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
1600 WEBSTER ST.
City
DAYTON
State
OH
ZIP
45404
Mailing
1600 WEBSTER ST., DAYTON, OH 45404
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336391
Employees
1100
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 33 exposed
Issued
Mar 16, 2016
Abate by
Apr 11, 2016
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;    The specific energy control procedure for the Radiator Furnace Conveyor Line involving electrical, 480 Volts AC and pneumatic, 90 psi, energy sources did not include the specific techniques for the control of these hazardous energy sources.
Recent events (3)
  • — F (S) $5000
  • — C (S) $5000
  • — Z (S) $5000

1910.147 C06 I B

Serious Gravity 5 1 instance 33 exposed
Issued
Mar 16, 2016
Abate by
Apr 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i)(B): The periodic inspection shall be conducted to correct any deviations or inadequacies identified.    The Company had not ensured that the review of the energy control procedures corrected the inadequacies in the specific energy control procedure for the Hytrol Furnace Conveyor Lines, Model ABEZ.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 F01

Deleted Serious Gravity 10 1 instance 33 exposed
Issued
Mar 16, 2016
Abate by
Apr 18, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(f)(1): Testing or positioning of machines, equipment or components thereof. In situations in which lockout or tagout devices must be temporarily removed from the energy isolating device and the machine or equipment energized to test or position the machine, equipment or component thereof, the following sequence of actions shall be followed:  Employee performing testing or positioning of machines, equipment did not perform the following:  deenergize all systems and reapply energy control procedures in accordance with paragraph (d) to continue servicing and maintenance.    On or about February 14, 2016, in the Production Area, Core Build 2, a general maintenance employee was replacing a sprocket and tightening the tension on the chain on the Hytrol Conveyor, E-44, when the following sequence was not followed prior to completion of the maintenance activity.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000