CHARLESTON, WV —
OSHA Inspection: SHIELD ROOFING AND CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SHIELD ROOFING AND CONSTRUCTION, LLC in 2829 KANAWHA BLVD. EAST, CHARLESTON, WV 25303 (NAICS 238160). OSHA activity number 341268282.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SHIELD ROOFING AND CONSTRUCTION, LLC
- Site address
- 2829 KANAWHA BLVD. EAST
- City
- CHARLESTON
- State
- WV
- ZIP
- 25303
- Mailing
- 206 4TH STREET EAST, SOUTH POINT, OH 45680
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B10
- Issued
- Mar 23, 2016
- Abate by
- Apr 18, 2016
- Penalty
- Initial $4,400 · Current $3,300 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. a.) 2829 Kanawha Blvd. East, Charleston, WV: On or about 02/22/16, employees were observed working on a 3/12 sloped roof approximately 12'6" above the ground without the use of fall protection. Shield Roofing and Construction, LLC., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(11), which was contained in OSHA inspection number 1062520, Citation 01, Item number 001a and was affirmed as a final order on 06/24/15, with respect to a workplace located at 405 Pennsylvania Avenue, Charleston, WV 25302.
Recent events (2)
- — I (R) $3300
- — Z (R) $4400
More inspections at Shield Roofing AND Construction, LLC