OSHA Inspection: KILLEEN PLUMBING COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KILLEEN PLUMBING COMPANY in 8594 LEWIS ROAD, OLMSTED FALLS, OH 44138 (NAICS 238220). OSHA activity number 341271534.

Watch Killeen Plumbing Company — free Get an email when a new federal OSHA severe-injury report for Killeen Plumbing Company is published. One employer, no account, unsubscribe in one click.
Site address
8594 LEWIS ROAD
City
OLMSTED FALLS
State
OH
ZIP
44138
Mailing
673 DOVER CENTER ROAD, WESTLAKE, OH 44145
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
24
Ownership type
A

2 citations on file for this inspection.

1926.651 C02

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:   On or about February 22, 2016, during the installation of a residential sanitary sewer system the employer did not ensure a stairway, ladder, and/or other safe means of egress was provided for an employee working in a trench approximately 9 feet long, with a depth of approximately 10 feet.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).    On or about February 22, 2016, during the installation of a residential sanitary sewer system the employer did not ensure an employee working inside a trench, with depth of approximately 10 feet and near 90 degree vertical walls, was protected from cave-ins by an adequately designed protection system.  The soil was classified type B.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341271534.