FORT MYERS, FL —
OSHA Inspection: SOUTHWEST UTILITY SYSTEMS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SOUTHWEST UTILITY SYSTEMS, INC. in U.S. 41 & CYPRESS LAKE DRIVE, FORT MYERS, FL 33912 (NAICS 237110). OSHA activity number 341273217.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTHWEST UTILITY SYSTEMS, INC.
- Site address
- U.S. 41 & CYPRESS LAKE DRIVE
- City
- FORT MYERS
- State
- FL
- ZIP
- 33912
- Mailing
- 16341 OLD US 41 SOUTH, FORT MYERS, FL 33912
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 C02
- Issued
- Jul 15, 2016
- Penalty
- Initial $4,200 · Current $2,520 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a. At the jobsite, a safe means of egress was not provided to an employee who was working in a trench with type "C" soil which was 5 feet 6 inches deep, 7 feet long, and 9 feet wide, exposing the employee to an entrapment hazard, on or about 2/24/16.
Recent events (2)
- — I (S) $2520
- — Z (S) $4200
1926.651 K02
- Issued
- Jul 15, 2016
- Penalty
- Initial $4,200 · Current $2,520 Reduced
General-duty citation text
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety: a. At the jobsite, an employee, who was the competent person, was locating and replacing 45 degree elbows on a 10 inch water line that was at the bottom of a 5-1/2 feet deep trench in type "C" soil that had nearly vertical walls, with cracks and fissures on the trench walls and standing water in the trench. Although he observed these conditions, he did not remove himself from the excavation.
Recent events (2)
- — I (S) $2520
- — Z (S) $4200
1926.652 A01
- Issued
- Jul 15, 2016
- Penalty
- Initial $4,200 · Current $2,520 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): a. At the jobsite, cave-in protection was not provided to an employee who was replacing 45 degree elbows on the 10 inch water line in a trench with type "C" soil which was 5 feet 6 inches deep, 7 feet long, and 9 feet wide, on or about 2/24/16.
Recent events (2)
- — I (S) $2520
- — Z (S) $4200
More inspections at Southwest Utility Systems, INC.
View Southwest Utility Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341273217.