Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOUTHWEST UTILITY SYSTEMS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOUTHWEST UTILITY SYSTEMS, INC. in U.S. 41 & CYPRESS LAKE DRIVE, FORT MYERS, FL 33912 (NAICS 237110). OSHA activity number 341273217.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southwest Utility Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Southwest Utility Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
U.S. 41 & CYPRESS LAKE DRIVE
City
FORT MYERS
State
FL
ZIP
33912
Mailing
16341 OLD US 41 SOUTH, FORT MYERS, FL 33912
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 15, 2016
Penalty
Initial $4,200 · Current $2,520 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  a.  At the jobsite, a safe means of egress was not provided to an employee who was working in a trench with type "C" soil which was 5 feet 6 inches deep, 7 feet long, and 9 feet wide, exposing the employee to an entrapment hazard, on or about 2/24/16.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $4200

1926.651 K02

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 15, 2016
Penalty
Initial $4,200 · Current $2,520 Reduced
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety:  a.  At the jobsite, an employee, who was the competent person, was locating and replacing 45 degree elbows on a 10 inch water line that was at the bottom of a 5-1/2 feet deep trench in type "C" soil that had nearly vertical walls, with cracks and fissures on the trench walls and standing water in the trench. Although he observed these conditions, he did not remove himself from the excavation.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $4200

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 15, 2016
Penalty
Initial $4,200 · Current $2,520 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c):  a.   At the jobsite, cave-in protection was not provided to an employee who was replacing 45 degree elbows on the 10 inch water line in a trench with type "C" soil which was 5 feet 6 inches deep, 7 feet long, and 9 feet wide, on or about 2/24/16.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $4200

View Southwest Utility Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341273217.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.