GLENCOE, IL —
OSHA Inspection: GF CARPENTRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GF CARPENTRY, INC. in 186 BEACH STREET, GLENCOE, IL 60022 (NAICS 238130). OSHA activity number 341277069.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GF CARPENTRY, INC.
- Site address
- 186 BEACH STREET
- City
- GLENCOE
- State
- IL
- ZIP
- 60022
- Mailing
- 514 S. GEORGE, MOUNT PROSPECT, IL 60056
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Jun 2, 2016
- Abate by
- Jun 8, 2016
- Penalty
- Initial $1,440 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) On or about February 25, 2016, employees were exposed to eye injury while operating pneumatic nail guns and electric saws without the benefit of eye protection. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1000
- — Z (S) $1440
1926.501 B13
- Issued
- Jun 2, 2016
- Abate by
- Jun 8, 2016
- Penalty
- Initial $12,600 · Current $7,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On or about February 25, 2016, employees were exposed to the hazard of falling approximately 17 feet while performing carpentry work from the first story deck of the building. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (W) $7400
- — Z (W) $12600
1926.403 B02
- Issued
- Jun 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about February 25, 2016, electrical junction boxes fitted with duplex receptacles were not secured in place when provided for use with portable cord and plug tools and equipment. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.403 I02 I
- Issued
- Jun 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50-volts or more were not guarded against accidental contact: a) On or about February 25, 2016, live parts of a duplex receptacle operating at 110 volts were not guarded against accidental contact. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.416 E01
- Issued
- Jun 2, 2016
- Abate by
- Jun 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) On or about February 25, 2016, worn and frayed electrical cords were used to supply electricity to tools and equipment at the site. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at GF Carpentry, INC.
View GF Carpentry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341277069.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.