SAN DIEGO, CA ·
OSHA Inspection: BERGELECTRIC CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BERGELECTRIC CORP. in HANGAR 5 MCAS MIRAMAR, SAN DIEGO, CA 92145 (NAICS 238210). OSHA activity number 341278059.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BERGELECTRIC CORP.
- Site address
- HANGAR 5 MCAS MIRAMAR
- City
- SAN DIEGO
- State
- CA
- ZIP
- 92145
- Mailing
- 650 OPPER STREET, ESCONDIDO, CA 92029
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 8
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.501 B01
- Issued
- Mar 29, 2016
- Penalty
- Initial $4,500 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) On or about February 25, 2016, at the MCAS Miramar worksite, employees installing photo voltaic panels on the roof of Hangar 5 were exposed to falls 17 feet to the lower level.
Recent events (3)
- · 2 (S) $3000
- · C (S) $4500
- · Z (S) $4500
1926.502 F02 II
- Issued
- Mar 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(2)(ii): The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface. (a) On or about February 25, 2016, at the MCAS Miramar worksite, the warning lines on the lower roof of Hangar 5 were sagging below 34 inches and the flags were contacting the walking and working surface. Employees were not protected from falling approximately 43 feet to the lower level.
Recent events (3)
- · 2 (S) $0
- · C (S) $0
- · Z (S) $0
1926.502 H01 V
- Issued
- Mar 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(h)(1)(v): The safety monitor had other responsibilities which could take the monitor's attention from the monitoring function: (a) On or about February 25, 2016, at the MCAS Miramar worksite, the safety monitor was performing other duties, such as but not limited to handing tools to an employee and holding photo voltaic panels. This exposed employees to fall hazards of at least 17 feet to the lower level.
Recent events (3)
- · 2 (S) $0
- · C (S) $0
- · Z (S) $0
More inspections at Bergelectric Corp.
View Bergelectric Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341278059.