OSHA Inspection: REDGRAVE ELECTRICAL MAINTENANCE INC

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of REDGRAVE ELECTRICAL MAINTENANCE INC in 321 CANAL ST, NEW YORK, NY 10013 (NAICS 238210). OSHA activity number 341278125.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Redgrave Electrical Maintenance INC for free Get an email when a new federal OSHA severe-injury report for Redgrave Electrical Maintenance INC is published. One employer, no account, unsubscribe in one click.
Site address
321 CANAL ST
City
NEW YORK
State
NY
ZIP
10013
Mailing
201 FLAMINGO ST, ATLANTIC BEACH, NY 11509
Inspection type
Programmed Related (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
20
Ownership type
Private (A)

1 citation on file for this inspection.

1926.403 E

Serious Gravity 10 1 instance 8 exposed
Issued
Apr 14, 2016
Abate by
May 10, 2016
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.403(e): All splices and joints and free ends of conductors were not covered with insulation equivalent to that of the conductors or with an insulating device designed for the purpose:   321/323 Canal St., NY, NY:  On or about 02/22/2016, Redgrave Electrical Maintenance exposed employees of E & S and Sons Corp. to hazards due to improper splicing of temporary electrical branch circuits.  The 12-3 non-metallic sheathed cable was spliced in locations on the first and third floor of the structure. Electrical tape was used to bind the cables but the conductors were left exposed and not properly insulated.    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $2800