OSHA Inspection: FLOOR TO CEILING CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FLOOR TO CEILING CONSTRUCTION in 4580 W. WALL ST., MIDLAND, TX 79703 (NAICS 238160). OSHA activity number 341278356.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Floor to Ceiling Construction — free Get an email when a new federal OSHA severe-injury report for Floor to Ceiling Construction is published. One employer, no account, unsubscribe in one click.
Site address
4580 W. WALL ST.
City
MIDLAND
State
TX
ZIP
79703
Mailing
3608 N. HANCOCK, ODESSA, TX 79762
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

13 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical agents.  Employees of Floor to Ceiling Construction were engaged in metal roofing activities and exposed to struck-by hazards while using an electric drill gun without eye protection.
Recent events (1)
  • — Z (S) $1200

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)  Employees of Floor to Ceiling Construction, were performing roofing activities from the second tier of a scaffold structure that was not fully planked and were exposed to a fall hazard in excess of 10 feet to the concrete below.
Recent events (1)
  • — Z (S) $2800

1926.451 B03

Serious Gravity 10 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling.  Employees of Floor to Ceiling Construction were engaged in roofing operations from a scaffold structure platform that was not 14 inches or less from the work and exposed to fall hazards in excess of 10 feet to the concrete below.
Recent events (1)
  • — Z (S) $0

1926.451 F03

Serious Gravity 10 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  Employees, of Floor to Ceiling Construction, performing roofing work from a welded frame scaffold structure that had not been inspected daily were exposed to fall hazards in excess of 10 ft. to the concrete below.
Recent events (1)
  • — Z (S) $0

1926.452 C04

Serious Gravity 10 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.452(c)(4): End frames of tubular welded frame scaffolding were not locked together vertically by use of pins or equivalent means in areas where uplift could occur.  Employees of Floor to Ceiling Construction were performing roofing activities from a welded scaffold structure that was not secured with locking pins and were exposed to fall hazards in excess of 10 ft. to the concrete below.
Recent events (1)
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.  Employees of Floor to Ceiling Construction were performing metal roofing activities from an unguarded welded frame scaffold structure and exposed to an unprotected fall in excess of 10 feet to concrete below.
Recent events (1)
  • — Z (S) $2800

1926.451 G04 I

Serious Gravity 10 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms.  Employees of Floor to ceiling Construction were performing roofing activities from the upper levels of a welded frame scaffold structure that did not have guardrails and exposed to a fall hazard in excess of 10 ft. to concrete below.
Recent events (1)
  • — Z (S) $0

1926.451 G04 III

Serious Gravity 10 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(iii): When midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent structural members are used, they were not installed between the top edge of the guardrail system and the scaffold platform.  Employees of Floor to Ceiling Construction were working from a welded frame scaffold structure platform that did not have midrails installed and exposed to fall hazards in excess of 10 ft. to concrete below.
Recent events (1)
  • — Z (S) $0

1926.454 A

Serious Gravity 10 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.  Employees of Floor to Ceiling Construction were performing roofing activities from a welded frame scaffold structure were not trained to recognize the hazards associated with the type of scaffold being used.
Recent events (1)
  • — Z (S) $2800

1926.451 F07

Serious Gravity 10 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.  Employees of Floor to Ceiling Construction, were working from a scaffold structure that had not been erected under the supervision and direction of a competent person qualified in scaffold erection and exposed to a fall hazard in excess of 10 feet to the concrete below.
Recent events (1)
  • — Z (S) $0

1926.454 B

Serious Gravity 10 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question.  Employees of Floor to Ceiling Construction who erected the scaffold structure were not trained by a competent person to recognize the hazards associated with the work.
Recent events (1)
  • — Z (S) $0

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  Employees of Floor to Ceiling Construction were performing roofing activities without fall protection and xposed to fall hazards in excess of six feet.
Recent events (1)
  • — Z (S) $2800

1926.602 D

Serious Gravity 5 1 instance 2 exposed
Issued
May 23, 2016
Abate by
Jun 10, 2016
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l):  Employees of Floor to Ceiling Construction were operating powered industrial trucks without certification and exposed to caught-in hazards.
Recent events (1)
  • — Z (S) $2400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341278356.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.