WACO, TX ·
OSHA Inspection: AXION INTERNATIONAL, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AXION INTERNATIONAL, INC. in 501 OLD HEWITT RD., WACO, TX 76712 (NAICS 326199). OSHA activity number 341279289.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AXION INTERNATIONAL, INC.
- Site address
- 501 OLD HEWITT RD.
- City
- WACO
- State
- TX
- ZIP
- 76712
- Mailing
- 501 OLD HEWITT RD., WACO, TX 76712
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 74
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Apr 11, 2016
- Abate by
- May 9, 2016
- Penalty
- Initial $4,200 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section. In the molding production area, the employer did not provide a specific procedure to control the over pressurization to the mold machine when it malfunctioned exposing employees to struck-by hazards.
Recent events (2)
- · I (S) $2520
- · Z (S) $4200
1910.147 C07 III A
- Issued
- Apr 11, 2016
- Abate by
- May 9, 2016
- Penalty
- Initial $4,200 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(iii)(A): Retraining was not provided for authorized and affected employees when there was a change in their job assignments, a change in machines, equipment or processes that presented a new hazard, or when there was a change in the procedure. In the molding production area, the employer did not train the employees on the hazards when there was a change of operation prior to running a new chemical product in the extrusion mold machine that caused a malfunction and over pressurization exposing employees to struck-by hazards.
Recent events (2)
- · I (S) $2520
- · Z (S) $4200
1910.303 F02
- Issued
- Apr 11, 2016
- Abate by
- May 9, 2016
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident. In the molding production area, the employer did not label the electrical panels with the voltage ratings exposing employees to electrical hazards.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
More inspections in this industry (NAICS 326199)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341279289.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.