Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STONYFIELD FARM, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STONYFIELD FARM, INC in 10 BURTON DRIVE, LONDONDERRY, NH 03053 (NAICS 311511). OSHA activity number 341279677.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stonyfield Farm, INC — free Get an email when a new federal OSHA severe-injury report for Stonyfield Farm, INC is published. One employer, no account, unsubscribe in one click.
Site address
10 BURTON DRIVE
City
LONDONDERRY
State
NH
ZIP
03053
Mailing
10 BURTON DRIVE, LONDONDERRY, NH 03053
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311511
Employees
275
Ownership type
A

2 citations on file for this inspection.

1910.119 D03 II

Serious Gravity 5 2 instances 275 exposed
Issued
Aug 1, 2016
Abate by
Sep 16, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices:    a. Engine Room- The employer failed to document process safety information for relief valves RV10, RV15, RV20, RV25, and RV28 to ensure that the relief valves were the proper type, size, and set pressure for protecting against an overpressure condition of thermosyphon oil coolers on screw compressors RC1, RC3, RC4, RC5, and RC6.    b. Roof- The employer failed to document that the ammonia relief vent discharging to atmosphere in a downward direction 10 feet from the roof surface between two roof top evaporative condensers and below the catwalks near the top of the two evaporative condensers complied with a recognized and generally accepted good engineering practice. The employer stated in their written program that they are adhering to ANSI/ASHRAE 15-2004 and verbally communicated that they are adhering to ANSI/IIAR 2-2014 in reference to ammonia relief vent discharge. The employer failed to comply with either standard.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5000

1910.119 J05

Serious Gravity 5 3 instances 275 exposed
Issued
Aug 1, 2016
Abate by
Sep 16, 2016
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that were outside acceptable limits (defined by the process safety information on paragraph (d) of this section) before use:    a. Engine Room- The employer failed to remove and replace relief valves RV10, RV15, RV20, RV25, and RV28 where the relief valves were protecting against an overpressure condition of liquid in the thermosyphon oil coolers on screw compressors RC1, RC3, RC4, RC5, RC6 and were not designed for liquid.    b. Roof- The employer failed to protect employees from exposure to ammonia where the ammonia relief vent was discharging to atmosphere in a downward direction 11 feet from the roof surface between the two roof top evaporative condensers and below the catwalks near the top of the two evaporative condensers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

View Stonyfield Farm, INC's full OSHA safety record →