OSHA Inspection: STOLTZE SPECIALTY PRODUCTS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STOLTZE SPECIALTY PRODUCTS, LLC in 333 SOUTH WISCONSIN AVENUE, MEDFORD, WI 54451 (NAICS 311999). OSHA activity number 341285674.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stoltze Specialty Products, LLC for free Get an email when a new federal OSHA severe-injury report for Stoltze Specialty Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
333 SOUTH WISCONSIN AVENUE
City
MEDFORD
State
WI
ZIP
54451
Mailing
335 SOUTH WISCONSIN AVENUE, MEDFORD, WI 54451
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311999
Employees
22
Ownership type
Private (A)

6 citations on file for this inspection.

1910.147 C04 II C

Serious Gravity 5 1 instance 6 exposed
Issued
May 5, 2016
Abate by
Jun 24, 2016
Penalty
Initial $4,500 · Current $3,150 Reduced
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them.    (a) Dryer area; The energy control procedure did not identify means for removing or transferring energy isolation devices or tagout devices.
Recent events (2)
  • · I (S) $3150
  • · Z (S) $4500

1910.147 C04 II D

Serious Gravity 5 1 instance 6 exposed
Issued
May 5, 2016
Abate by
Jun 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures:  (a) Dryer area; The energy isolation procedure did not identify the steps required for verifying effectiveness of energy isolation and lockout devices after they were applied.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 D03

Serious Gravity 10 2 instances 6 exposed
Issued
May 5, 2016
Abate by
May 19, 2016
Penalty
Initial $6,300 · Current $4,410 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    (a) Dryer area; On or about January 18, 2016, a means of isolation was not utilized during jam clearing operations on powered screw type augers/conveyors.
Recent events (2)
  • · I (S) $4410
  • · Z (S) $6300

1910.147 D04 I

Serious Gravity 10 2 instances 6 exposed
Issued
May 5, 2016
Abate by
May 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.  (a) Dryer area; On or about January 18, 2016, Lockout device(s) were not affixed to isolation point(s) during jam clearing operations on equipment, such as but not limited; to powered cross-feed augers and the flaker.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 F04

Serious Gravity 10 1 instance 8 exposed
Issued
May 5, 2016
Abate by
May 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(4): During shift or personnel changes, specific procedures were not utilized to ensure the continuity of lockout or tagout protection, including provision for the orderly transfer of lockout or tagout devices between off-going and oncoming employees to minimize exposure to hazards from the unexpected energization or start-up of the machine or equipment, or the release of stored energy.  (a) Dryer area; On or about January 18, 2016, The procedure used for transferring lockout between off-going and oncoming employees did not ensure that the continuity of lockout was maintained.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A02

Serious Gravity 10 4 instances 6 exposed
Issued
May 5, 2016
Abate by
Jun 24, 2016
Penalty
Initial $6,300 · Current $4,410 Reduced
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:    (a) Dryer area; Guards on screw type auger conveyors were not secured and/or safeguarded to prevent them from being easily bypassed.