Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GENESIS HEALTH CARE, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of GENESIS HEALTH CARE, INC. in 813 KELLER LANE, TUSCUMBIA, AL 35674 (NAICS 623110). OSHA activity number 341287548.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Genesis Health Care, INC. — free Get an email when a new federal OSHA severe-injury report for Genesis Health Care, INC. is published. One employer, no account, unsubscribe in one click.
Site address
813 KELLER LANE
City
TUSCUMBIA
State
AL
ZIP
35674
Mailing
813 KELLER LANE, TUSCUMBIA, AL 35674
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
88
Ownership type
A

3 citations on file for this inspection.

1910.1030 C01 IV B

Other-than-serious 1 instance 30 exposed
Issued
Aug 1, 2016
Abate by
Aug 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(c)(1)(iv)(B): The review and update of the exposure control plan did not document annually consideration and implementation of appropriate commercially available and effective safer medical devices designed to eliminate or minimize occupational exposure:  a)  On or about 02/18/16 - Facility, the annual review and consideration of safer medical devices was not conducted and documented in the employer's written exposure control plan.
Recent events (1)
  • — Z (O) $0

1910.1030 C01 V

Other-than-serious 1 instance 30 exposed
Issued
Aug 1, 2016
Abate by
Aug 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(c)(1)(v): The employer, who is required to establish an Exposure Control Plan, did not solicit input from non-managerial employees responsible for direct patient care who are potentially exposed to injuries from contaminated sharps in the identification, evaluation and selection of effective engineering and work practice controls and did not document the solicitation in the Exposure Control plan:  a) On or about 02/18/16 - Facility, the Exposure Control Plan did not include the documentation of the review of effective engineering and work practice controls by non-managerial employees.
Recent events (1)
  • — Z (O) $0

1910.1030 H05

Other-than-serious 1 instance 30 exposed
Issued
Aug 1, 2016
Abate by
Aug 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(h)(5)(i):  The employer did not establish and maintain a sharps injury log for the recording of percutaneous injuries from contaminated sharps:    a) On or about 02/18/16 - Facility, a Sharps injury log was not established for the recording of all percutaneous injuries in the facility occurring from contaminated sharps. The log should include the following information; The type of device, Brand of the Device, Work Area, and a description of how the incident occurred.