VICTOR, NY ·
OSHA Inspection: AUSTIN SPENCER COLLISION INC. DBA ASC AUTOMOTIVE
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of AUSTIN SPENCER COLLISION INC. DBA ASC AUTOMOTIVE in 2 RAILROAD AVE., VICTOR, NY 14564 (NAICS 811121). OSHA activity number 341288538.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUSTIN SPENCER COLLISION INC. DBA ASC AUTOMOTIVE
- Site address
- 2 RAILROAD AVE.
- City
- VICTOR
- State
- NY
- ZIP
- 14564
- Mailing
- 2 RAILROAD AVE., VICTOR, NY 14564
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 16
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.106 D03 II A
- Issued
- Mar 8, 2016
- Penalty
- Initial $1,200 · Current $780 Reduced
General-duty citation text
29 CFR 1910.106(d)(3)(ii)(a): The door of the metal storage cabinet(s) for flammable and combustible liquids not provided with a three point lock: a) Paint Mixing Area, on or about 2/29/16: Flammable storage cabinet containing miscellaneous flammable items had a broken handle.
Recent events (2)
- · I (S) $780
- · Z (S) $1200
1910.106 E06 I
- Issued
- Mar 8, 2016
- Abate by
- Mar 21, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions against the ignition of flammable vapors were not taken: a) Paint Mixing Area, on or about 2/29/16: Employees dispense from a 16 gallon container of 1501 Premium Wash Thinner a flammable material, and the container was not grounded.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.106 E06 II
- Issued
- Mar 8, 2016
- Abate by
- Mar 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a) Paint Mixing Area, on or about 2/29/16: Employee was dispensing a flammable material from a 16 gallon drum to a secondary container with no means of electrically interconnecting the nozzle and the portable container.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 E01
- Issued
- Mar 8, 2016
- Abate by
- Mar 31, 2016
- Penalty
- Initial $2,000 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Note: The employer may discontinue an employees medical evaluations when the employee is no longer required to use a respirator. a) Auto Prep Area, on or about 2/29/16: Employees required to wear half face air purifying respirators had not been provided with a medical evaluation.
Recent events (2)
- · I (S) $1300
- · Z (S) $2000
1910.134 F02
- Issued
- Mar 8, 2016
- Abate by
- Mar 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employer did not ensure that an employee using a tight fitting face-piece respirator was fit tested prior to initial use of the respirator, whenever a different respirator face-piece (size, style, model or make) was used, and at least annually thereafter: a) Auto Prep Area, on or about 2/29/16: Employees required to wear half face air purifying respirators had not been fit tested.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 G02 I
- Issued
- Mar 8, 2016
- Abate by
- Mar 21, 2016
- Penalty
- Initial $2,000 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: a) Hallway Area Between Paint Booths, Brass Department, on or about 2/29/16: A 120/240 volt breaker panel box located had two blanks missing.
Recent events (2)
- · I (S) $1300
- · Z (S) $2000
1910.304 F01 IV
- Issued
- Mar 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less were not readily accessible to each employee or authorized building management personnel: a) Hallway Area Between Paint Booths, on or about 2/29/16: Access to a 120/240 volt breaker panel box was blocked by several miscellaneous large items.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 811121)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341288538.