CORSICANA, TX —
OSHA Inspection: NALCO CHAMPION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NALCO CHAMPION in 2733 EAST HWY 31, CORSICANA, TX 75109 (NAICS 325998). OSHA activity number 341289080.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NALCO CHAMPION
- Site address
- 2733 EAST HWY 31
- City
- CORSICANA
- State
- TX
- ZIP
- 75109
- Mailing
- P.O. BOX 1898, CORSICANA, TX 75151
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 130
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.119 D03 II
- Issued
- Jul 25, 2016
- Abate by
- Aug 15, 2016
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that the equipment in the process complied with recognized and generally accepted good engineering practices. This violation was observed at NALCO Champion on or about March 1, 2016 and at times prior thereto and after where the employer failed to document that the pressure relief device was set at or below the design maximum allowable working pressure of Reactor 4 in accordance with recognized and generally accepted good engineering practice such as ASME Boiler and Pressure Vessel Code Section VIII.
Recent events (3)
- — F (O) $3500
- — C (S) $7000
- — Z (S) $7000
1910.119 J05
- Issued
- Jul 25, 2016
- Abate by
- Aug 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that were outside acceptable limits (defined by the process safety information on paragraph (d) of this section) before use This violation was observed at NALCO Champion on or about March 1, 2016 and at times prior thereto and after where the employer failed to correct deficiencies in equipment that were outside acceptable limits when the pressure relief device was set above the design maximum allowable working pressure of Reactor 4.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.119 J02
- Issued
- Jul 25, 2016
- Abate by
- Aug 15, 2016
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish and implement written procedures to maintain the on-going mechanical integrity of process equipment. The violation was observed at NALCO Champion on or about March 1, 2016 and at times prior thereto where the employer failed to establish and implement written procedures to maintain the on-going mechanical integrity draft policy for Reactor 3, E-801, E-909, Reactor 8, and V-401.
Recent events (3)
- — F (O) $1500
- — C (S) $3000
- — Z (S) $3000
1910.119 J04 I
- Issued
- Jul 25, 2016
- Abate by
- Aug 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(4)(i): The employer did not perform inspection and tests on process equipment The violation was observed at NALCO Champion on or about March 1, 2016 and at times prior thereto and after where the employer failed to perform inspection and tests on Reactor 7.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.119 J04 II
- Issued
- Jul 25, 2016
- Abate by
- Aug 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(4)(ii): Inspections and testing procedures performed on process equipment to maintain its mechanical integrity, did not follow recognized and generally accepted good engineering practices. a. The violation was observed on or about March 1, 2016 and at times prior thereto in the Amines plant at Nalco Champion where the employer failed to ensure inspections records for thickness monitoring were reviewed for E-801, reactor 3, reactor 4, reactor 6, reactor 8, V-009, V-1122, E-909, R-900, V-206 and V-401. The corrosion monitoring reported indicated that the retirement thickness had nor been determined or calculated by the formulas by the employer. The corrosion rates(short and long term) were not established by the employer.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1910.119 J04 III
- Issued
- Jul 25, 2016
- Abate by
- Aug 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment was not consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience. The violation was observed on or about March 1, 2016 and times prior thereto in the Amines plant at Nalco Champion where the employer failed to ensure the frequency of inspections and tests of process equipment were in accordance with RAGAGEP such as API 510.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Jul 25, 2016
- Abate by
- May 30, 2017
- Penalty
- Initial $2,550 · Current $1,275 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose. In the old warehouse, a panel box used to energize the lights and electrical outlets was missing the door cover exposing employees to electrical hazards.
Recent events (3)
- — F (O) $1275
- — C (S) $2550
- — Z (S) $2550
1910.305 G01 IV A
- Issued
- Jul 25, 2016
- Penalty
- Initial $2,550 · Current $1,275 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. In the old warehouse area, an extension cord, wrapped around the steel beams located on the ceiling was used as permanent wiring to energize the water pump exposing employees to electrical shock hazards.
Recent events (3)
- — F (O) $1275
- — C (S) $2550
- — Z (S) $2550
More inspections at Nalco Champion
View Nalco Champion's full OSHA safety record →
More inspections in this industry (NAICS 325998)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341289080.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.