Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: BAYSTATE HOME GUARD, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BAYSTATE HOME GUARD, INC. in 19-35 LEYLAND STREET, DORCHESTER, MA 02125 (NAICS 562910). OSHA activity number 341290906.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Baystate Home Guard, INC. for free Get an email when a new federal OSHA severe-injury report for Baystate Home Guard, INC. is published. One employer, no account, unsubscribe in one click.
Site address
19-35 LEYLAND STREET
City
DORCHESTER
State
MA
ZIP
02125
Mailing
38 DAWES STREET, SPRINGFIELD, MA 01101
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
15
Ownership type
A

4 citations on file for this inspection.

1926.1101 F01 II

Serious Gravity 5 1 instance 12 exposed
Issued
May 11, 2016
Abate by
Jun 30, 2016
Penalty
Initial $1,600 · Current $1,600

Hazardous substances 9020

29 CFR 1926.1101(f)(1)(ii): Determinations of employee exposure were not made from breathing zone air samples that were representative of the 8-hour time weighted average exposures for each employee:  Location: Worksite   Employees were removing asbestos-containing thermal system insulation, popcorn ceiling surfacing material, caulking, roof flashing, and joint compound, and the personal air monitoring duration was not adequate.  Personal air monitoring must represent full shift, or 8 hour, exposure for employees in each work area.
Recent events (1)
  • · Z (S) $1600

1926.1101 F02 I

Other-than-serious 1 instance 12 exposed
Issued
May 11, 2016
Abate by
Jun 30, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 9020

29 CFR 1926.1101(f)(2)(i): The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation or workplace:   Location: Worksite   Employees were exposed to asbestos from removing asbestos-containing thermal system insulation, popcorn ceiling surfacing material, caulking, roof flashing, and joint compound, and the employer had not ensured that a competent person performed an exposure assessment immediately before or at the initiation of the abatement.
Recent events (1)
  • · Z (O) $0

1926.1101 F03 I

Other-than-serious 1 instance 12 exposed
Issued
May 11, 2016
Abate by
Jun 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1101(f)(3)(i): The employer failed to conduct daily monitoring that was representative of the exposure of each employee assigned to work in regulated areas and performing Class I or II work.  Location: Worksite   Employees were exposed to asbestos from removing asbestos-containing thermal system insulation, popcorn ceiling surfacing material, caulking, roof flashing, and joint compound, and the employer had not ensured that a competent person performed daily monitoring representative of the exposure of each employee assigned to work in the regulated areas.
Recent events (1)
  • · Z (O) $0

1926.1101 H03 IV A

Other-than-serious 1 instance 12 exposed
Issued
May 11, 2016
Abate by
Jun 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1101(h)(3)(iv)(A): The employer did not provide employees with a tight-fitting powered air-purifying respirator operated in the pressure-demand mode and equipped with either HEPA egress cartridges or an auxiliary positive-pressure self-contained breathing apparatus, whenever the employees were in regulated area performing Class I asbestos work for which a negative exposure assessment was not available or the exposure assessment indicated that the exposure level will be at or below 1 fiber per cubic centimeter as an 8-hour time weighted average:  Location: Worksite   Employees were exposed to asbestos while performing Class I work involving asbestos-containing thermal system insulation and popcorn ceiling material. They were wearing half-face negative pressure respirators, but the employer had not demonstrated that these were adequate based on a negative exposure assessment or by performing representative 8-hr time weighted average monitoring.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341290906.