DORCHESTER, MA ·
OSHA Inspection: BAYSTATE HOME GUARD, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BAYSTATE HOME GUARD, INC. in 19-35 LEYLAND STREET, DORCHESTER, MA 02125 (NAICS 562910). OSHA activity number 341290906.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BAYSTATE HOME GUARD, INC.
- Site address
- 19-35 LEYLAND STREET
- City
- DORCHESTER
- State
- MA
- ZIP
- 02125
- Mailing
- 38 DAWES STREET, SPRINGFIELD, MA 01101
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562910
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.1101 F01 II
- Issued
- May 11, 2016
- Abate by
- Jun 30, 2016
- Penalty
- Initial $1,600 · Current $1,600
9020
General-duty citation text
29 CFR 1926.1101(f)(1)(ii): Determinations of employee exposure were not made from breathing zone air samples that were representative of the 8-hour time weighted average exposures for each employee: Location: Worksite Employees were removing asbestos-containing thermal system insulation, popcorn ceiling surfacing material, caulking, roof flashing, and joint compound, and the personal air monitoring duration was not adequate. Personal air monitoring must represent full shift, or 8 hour, exposure for employees in each work area.
Recent events (1)
- · Z (S) $1600
1926.1101 F02 I
- Issued
- May 11, 2016
- Abate by
- Jun 30, 2016
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1926.1101(f)(2)(i): The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation or workplace: Location: Worksite Employees were exposed to asbestos from removing asbestos-containing thermal system insulation, popcorn ceiling surfacing material, caulking, roof flashing, and joint compound, and the employer had not ensured that a competent person performed an exposure assessment immediately before or at the initiation of the abatement.
Recent events (1)
- · Z (O) $0
1926.1101 F03 I
- Issued
- May 11, 2016
- Abate by
- Jun 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(f)(3)(i): The employer failed to conduct daily monitoring that was representative of the exposure of each employee assigned to work in regulated areas and performing Class I or II work. Location: Worksite Employees were exposed to asbestos from removing asbestos-containing thermal system insulation, popcorn ceiling surfacing material, caulking, roof flashing, and joint compound, and the employer had not ensured that a competent person performed daily monitoring representative of the exposure of each employee assigned to work in the regulated areas.
Recent events (1)
- · Z (O) $0
1926.1101 H03 IV A
- Issued
- May 11, 2016
- Abate by
- Jun 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(h)(3)(iv)(A): The employer did not provide employees with a tight-fitting powered air-purifying respirator operated in the pressure-demand mode and equipped with either HEPA egress cartridges or an auxiliary positive-pressure self-contained breathing apparatus, whenever the employees were in regulated area performing Class I asbestos work for which a negative exposure assessment was not available or the exposure assessment indicated that the exposure level will be at or below 1 fiber per cubic centimeter as an 8-hour time weighted average: Location: Worksite Employees were exposed to asbestos while performing Class I work involving asbestos-containing thermal system insulation and popcorn ceiling material. They were wearing half-face negative pressure respirators, but the employer had not demonstrated that these were adequate based on a negative exposure assessment or by performing representative 8-hr time weighted average monitoring.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 562910)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341290906.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.