PITTSBURGH, PA —
OSHA Inspection: REPAL CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of REPAL CONSTRUCTION in 4800 PENN AVENUE, PITTSBURGH, PA 15224 (NAICS 236220). OSHA activity number 341293587.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REPAL CONSTRUCTION
- Site address
- 4800 PENN AVENUE
- City
- PITTSBURGH
- State
- PA
- ZIP
- 15224
- Mailing
- 11075 PARKER DRIVE, NORTH HUNTINGDON, PA 15642
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 25
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.153 O
- Issued
- Mar 9, 2016
- Abate by
- Mar 21, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.153(o): When damage to LP-Gas systems from vehicular traffic was a possibility, precautions against such damage were not taken: (a) Jobsite, 4800 Penn Avenue, Pittsburgh, PA: On or about 02/29/16 two 1000 gallon propane tanks used for heating the building were not adequately protected from damage from vehicular traffic. A chain link fence was positioned directly next to the tanks and the alley way where vehicles travel and park and would not protect the tanks from damage. In addition, aerial lifts traveled on the inside of the fenced work area in and around the tanks and was only separated by flat pieces of metal sheeting positioned on the ground.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.602 D
- Issued
- Mar 9, 2016
- Abate by
- Apr 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l): Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178: (a) Jobsite, 4800 Penn Avenue, Pittsburgh, PA: On or about 02/29/16 an employee who was operating the Sky Trak 6042 powered industrial vehicle had not been trained and evaluated to ensure they were capable of operating the equipment safely.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.404 F06
- Issued
- Mar 9, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: (a) Jobsite, 4800 Penn Avenue, 2nd Floor, Pittsburgh, PA: On or about 02/29/16 a flexible cord being used to power a heater was missing the ground pin thereby not providing a permanent and continuous path to ground.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Repal Construction
View Repal Construction's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341293587.