Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LABRAN CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LABRAN CONSTRUCTION LLC in 4429 LOWELL STREET NW, WASHINGTON, DC 20016 (NAICS 236118). OSHA activity number 341293959.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Labran Construction LLC — free Get an email when a new federal OSHA severe-injury report for Labran Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
4429 LOWELL STREET NW
City
WASHINGTON
State
DC
ZIP
20016
Mailing
2328 MONTGOMERY STREET, SILVER SPRING, MD 20910
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
10
Ownership type
A

4 citations on file for this inspection.

1926.404 F06

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 10, 2016
Abate by
Jun 20, 2016
Penalty
Initial $1,320 · Current $700 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous    a) On or about March 2, 2016; roof of the residential home (Westside); the portable extension cord used to provide power to the sawzall had the ground pin missing.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $700
  • — Z (S) $1320

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 10, 2016
Abate by
Jun 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) On or about March 2, 2016; second floor of the residential home; the employees were using a 5-foot fiberglass stepladder in the closed position to access the work area exposing them to a 10-foot fall to the wooden deck or 20 feet to ground level due to being positioned near a wall opening.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 10, 2016
Abate by
Jun 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:   a) On or about March 2, 2016; second floor of the residential home; employees were using the top step of a 5-foot stepladder that was used to access the working platform.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Repeat Gravity 10 3 instances 3 exposed
Issued
Jun 10, 2016
Abate by
Jun 20, 2016
Penalty
Initial $6,160 · Current $5,900 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) On or about March 2, 2016; Roof area of residential home (Westside); employees were exposed to an estimated fall of 30 footfall to ground level while removing the roof on the residential home; employees were tied off by tying a rope around their waist and anchoring by tying the rope around one of rafters.     b) On or about March 2, 2016; floor openings located at on the second floor at the stair system;  were not properly guarded to prevent employees from falling 10 feet to the lower level.    c) On or about March 2, 2016; wall openings located on the second floor; were not properly guarded to prevent the employees from falling 12 feet to ground level while working near the openings.     The Labran Construction LLC was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number1037237, citation number 1, item number 1a and was affirmed as a final order on 4/13/2015, with respect to a workplace located at 1100 W Street NW Washington DC 20009.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (R) $5900
  • — Z (R) $6160

View Labran Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341293959.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.