Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUALITY METAL FINISHING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of QUALITY METAL FINISHING, INC. in 15 S.W. 25TH ST., OKLAHOMA CITY, OK 73109 (NAICS 332813). OSHA activity number 341298974.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Metal Finishing, INC. — free Get an email when a new federal OSHA severe-injury report for Quality Metal Finishing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15 S.W. 25TH ST.
City
OKLAHOMA CITY
State
OK
ZIP
73109
Mailing
15 S.W. 25TH ST., OKLAHOMA CITY, OK 73109
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 20, 2016
Abate by
May 12, 2016
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  On or about March 3, 2016, and times prior thereto, Building #2, suitable facilities for quick drenching or flushing of eyes and body were not provided within the work area for employees exposed to corrosive materials such as, but not limited to, Chromic Acid Flake, Hydrated Lime, and Hydrochloric Acid.  Employees were exposed to the hazard of hazards of corrosive materials in eyes and/or on skin.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.305 G01 IV D

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 20, 2016
Abate by
May 5, 2016
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces:  On or about March 3, 2016, and times prior thereto, Building #2, an extension cord was attached to electrical conduit on wall and attached to ceiling.  Employees were exposed to the hazard of electric shock.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.305 G02 II

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 20, 2016
Abate by
Apr 28, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap.    On or about March 3, 2016, and times prior thereto, Building #1, 240 volt flexible cable for pump was not used in continuous lengths without splice.  Employees were exposed to the hazard of electric shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B06

Other-than-serious 2 instances 3 exposed
Issued
Apr 20, 2016
Abate by
May 5, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source:  On or about March 3, 2016, and times prior thereto, Building #2, the following exit signs were not illuminated by a reliable light source.   a) Exit on north wall b) Exit on east wall  Employees were exposed to the hazards associated with fire.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 3 instances 3 exposed
Issued
Apr 20, 2016
Abate by
Apr 28, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  On or about March 3, 2016, and times prior thereto, Building #2, portable fire extinguishers in the following areas were not inspected monthly.    a) North wall b) East wall c) Compressor Room  Employees were exposed to the hazards associated with fire.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Quality Metal Finishing, INC.'s full OSHA safety record →