MOULTRIE, GA ·
OSHA Inspection: CANFOR BEADLES, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CANFOR BEADLES, LLC in 900 6TH STREET NE, MOULTRIE, GA 31776 (NAICS 321113). OSHA activity number 341303857.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CANFOR BEADLES, LLC
- Site address
- 900 6TH STREET NE
- City
- MOULTRIE
- State
- GA
- ZIP
- 31776
- Mailing
- 900 6TH STREET NE, MOULTRIE, GA 31776
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 106
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Jul 8, 2016
- Abate by
- Aug 3, 2016
- Penalty
- Initial $4,500 · Current $3,375 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a) At the Cut Up Saw, on or about March 3, 2016, the employer did not clearly and specifically outline the techniques to control stored energy while performing maintenance activities on the equipment exposing employees to amputation hazards.
Recent events (2)
- · I (S) $3375
- · Z (S) $4500
1910.147 D05 I
- Issued
- Jul 8, 2016
- Abate by
- Aug 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: (a) At the Cut Up Saw, on or about March 3, 2016, the employer did not ensure stored energy was relieved or restrained while employees were performing maintenance activities on the equipment exposing them to amputation hazards.