FREMONT, NE ·
OSHA Inspection: FREMONT MONUMENT CO.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FREMONT MONUMENT CO. in 1835 N. SOMERS ST., FREMONT, NE 68025 (NAICS 327991). OSHA activity number 341304913.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FREMONT MONUMENT CO.
- Site address
- 1835 N. SOMERS ST.
- City
- FREMONT
- State
- NE
- ZIP
- 68025
- Mailing
- 235 W. MILITARY AVE., FREMONT, NE 68025
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.23 C01
- Issued
- Jul 11, 2016
- Penalty
- Initial $1,156 · Current $809 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent): The employer failed to ensure that a storage platform in the Warehouse had standard railings consisting of a top rail, mid-rail, and toeboards.
Recent events (2)
- · I (S) $809.2
- · Z (S) $1156
1910.23 D01
- Issued
- Jul 11, 2016
- Penalty
- Initial $867 · Current $607 Reduced
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers shall be equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails: The employer failed to ensure that a flight of stairs in the Warehouse had a midrail.
Recent events (2)
- · I (S) $606.9
- · Z (S) $867
1910.22 D01
- Issued
- Jul 11, 2016
- Abate by
- Aug 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed to the building: The employer is failing to ensure the mezzanine on which materials and boxes were stored did not have the load rating marked on it.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 327991)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341304913.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.