OSHA Inspection: UTSLER INVESTMENTS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UTSLER INVESTMENTS in 7665 E ARAPAHOE ROAD, CENTENNIAL, CO 80112 (NAICS 811111). OSHA activity number 341309706.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Utsler Investments — free Get an email when a new federal OSHA severe-injury report for Utsler Investments is published. One employer, no account, unsubscribe in one click.
Establishment
UTSLER INVESTMENTS
Site address
7665 E ARAPAHOE ROAD
City
CENTENNIAL
State
CO
ZIP
80112
Mailing
6834 S UNIVERSITY BLVD #439, CENTENNIAL, CO 80122
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
12
Ownership type
A

6 citations on file for this inspection.

1910.215 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 16, 2016
Abate by
Mar 24, 2016
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:  (a)  On or about March 8, 2016, employees were exposed to struck by hazards in that the Craftsman bench grinder was not provided with a spindle guard.  Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 16, 2016
Abate by
Mar 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:  (a) On or about March 8, 2016, the employer exposed employees to stuck-by hazards due to the bench grinder, located in the automotive pit area, not equipped with a work rest.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 A02

Other-than-serious 1 instance 12 exposed
Issued
Mar 16, 2016
Abate by
Mar 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:  a)  On or about March 8, 2016, and at times prior, employees were exposed to slips and falls due to oil on the floor throughout the automotive pit area.    Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.36 G02

Other-than-serious 1 instance 12 exposed
Issued
Mar 16, 2016
Abate by
Mar 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  a)  On or about March 8, 2016, the employer exposed employees to hazards associated with lack of adequate egress in that the exit located in the storage room of the shop measured 19 inches wide.   Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.106 E09 III

Other-than-serious 1 instance 12 exposed
Issued
Mar 16, 2016
Abate by
Mar 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:  (a)  On or about March 8, 2016, the employer exposed employees to fire hazards in that the covered metal receptacles containing hazardous materials, were not disposed of on a daily basis.  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 12 exposed
Issued
Mar 16, 2016
Abate by
Mar 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a)  On or about February 12, 2015, the employer did not maintain a clear distance of 3 feet in front of the circuit breaker panels and transformers in order to provide access for emergency maintenance.   Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341309706.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.