CENTENNIAL, CO —
OSHA Inspection: UTSLER INVESTMENTS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UTSLER INVESTMENTS in 7665 E ARAPAHOE ROAD, CENTENNIAL, CO 80112 (NAICS 811111). OSHA activity number 341309706.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UTSLER INVESTMENTS
- Site address
- 7665 E ARAPAHOE ROAD
- City
- CENTENNIAL
- State
- CO
- ZIP
- 80112
- Mailing
- 6834 S UNIVERSITY BLVD #439, CENTENNIAL, CO 80122
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.215 A02
- Issued
- Mar 16, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: (a) On or about March 8, 2016, employees were exposed to struck by hazards in that the Craftsman bench grinder was not provided with a spindle guard. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.215 A04
- Issued
- Mar 16, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: (a) On or about March 8, 2016, the employer exposed employees to stuck-by hazards due to the bench grinder, located in the automotive pit area, not equipped with a work rest. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A02
- Issued
- Mar 16, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: a) On or about March 8, 2016, and at times prior, employees were exposed to slips and falls due to oil on the floor throughout the automotive pit area. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.36 G02
- Issued
- Mar 16, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. a) On or about March 8, 2016, the employer exposed employees to hazards associated with lack of adequate egress in that the exit located in the storage room of the shop measured 19 inches wide. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.106 E09 III
- Issued
- Mar 16, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: (a) On or about March 8, 2016, the employer exposed employees to fire hazards in that the covered metal receptacles containing hazardous materials, were not disposed of on a daily basis. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Mar 16, 2016
- Abate by
- Mar 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about February 12, 2015, the employer did not maintain a clear distance of 3 feet in front of the circuit breaker panels and transformers in order to provide access for emergency maintenance. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811111)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341309706.